Error Code Chart - Frigidaire AGQ7000EE - 5.8 cu.ft. Affinity Gas Dryer Datasheet

Data sheet
Hide thumbs Also See for AGQ7000EE - 5.8 cu.ft. Affinity Gas Dryer:
Table of Contents

Advertisement

Available languages

Available languages

Error
code
E11
Fill time too long.
E13
Water leak in tub or air leak in air bell.
E21
Water not pumping out fast enough.
E23
Drain pump relay on control board failed, wire off pump or pump
defective.
E24
Drain pump relay on control board failed.
E31
Pressure sensor not communicating with control board.
E35
Pressure sensor indicates water overfill.
E36
Console control board problem.
E38
Air chamber clogged or pressure sensor defective.
E41
Control board thinks the door switch is open.
E43
Console control board thinks the door locking device has failed.
E44
Console control board problem.
E45
Console control board problem.
E46
Console control board problem.
E47
Console control board thinks the door PTC circuit is open in spin. Refer to test (7).
E48
Console control board thinks the door PTC circuit is closed.
E52
Bad signal from tacho generator.
E56
High motor current.
E57
High current on inverter.
E58
High current on motor phase.
E59
No tacho signal for 3 seconds.
E5A High temperature on heat sink caused by overloading.
E5B High temperature on heat sink.
E5C High temperature on heat sink.
E5D Communication problem.
E5E Communication problem.
E5F
Communication problem.
E66
Heating element relay failure.
E67
Input voltage on microprocessor incorrect.
E68
Current leakage to ground on heater or fuse opened.
E71
Wash NTC failure.
E74
Wash temperature does not increase.
E75
Water temperature sensor circuit.
E82
Console control board problem.
E83
Console control board problem.
E91
Comunnication error between UI board and console control board. Refer to test (16).
E93
Console control board problem.
E94
Console control board problem.
E95
Communication error.
E97
Console control board problem.
E98
Console control board problem.
EB1 Incoming power frequency out of limits.
EB2 Incoming line voltage above 130 VAC.
EB3 Incoming line voltage below 90 VAC.
EBE Console control board problem.
EBF Console control board problem.
EF1
Clogged drain pump.
EF2
Too much soap.

Error code chart

Fault condition
2
Check
Refer to test (1).
Refer to test (2).
Refer to test (3).
Replace console control board, wire or
pump.
Replace console control board.
Refer to test (4).
Refer to test (5).
Replace console control board.
Check air chamber, rpl press. sensor.
Refer to test (6).
Refer to test (7).
Replace console control board.
Replace console control board.
Replace console control board.
Refer to test (7).
Refer to test (8).
Refer to test (9).
Refer to test (9).
Refer to test (9).
Refer to test (10).
Test first-if bad-rpl speed control brd.
Replace speed control board.
Replace speed control board.
Refer to test (11).
Refer to test (11).
Refer to test (11).
Refer to test (14).
Refer to test (15).
Refer to test (14 & 15).
Refer to test (15).
Wire off NTC - rpl water valve.
Refer to test (12).
Replace console control board.
Replace console control board.
Replace console control board.
Replace console control board.
Replace console control board.
Replace console control board.
Replace console control board.
Refer to test (13).
Check voltage at outlet. If < 130VAC,
replace the console control board.
Check voltage at outlet. If > 90VAC,
replace the console control board.
Replace console control board.
Replace console control board.
Unclog the drain pump.
Advise customer to reduce the amount
of soap they are using.