Wiring Diagram 39726.501 & 39726.506; Specifications-Heat Pump - Dometic 39626.501 Installation Instructions Manual

Self-contained air conditioner & heat pump for recreational vehicle
Table of Contents

Advertisement

WHT
G-Y
BLK
DIP SWITCHES
ON
CIR.#1
1
2
3
4
5
P1
115 VAC 60 Hz 1O
115 VAC 60 Hz 1O
USE COPPER CONDUCTORS
USE COPPER CONDUCTORS
ONLY
P2
FREEZE
CONTROL
P3
P4
P5
AMB.
FIELD WIRING MUST
FIELD WIRING MUST
SENSOR
COMPLY WITH THE
COMPLY WITH THE
NATIONAL ELECTRIC CODE
NATIONAL ELECTRIC CODE
F1
3 AMP FUSE
RED
BLK
BLU
BLU
YEL
YEL
PASSED
DIELECTRIC
WHT
CIR.#2
115 VAC 60 Hz 1O
115 VAC 60 Hz 1O
USE COPPER CONDUCTORS
USE COPPER CONDUCTORS
ONLY
BLK
G-Y
WHT
2.7 SPECIFICATIONS - HEAT PUMP
System Model
Nominal BTU Capacity
Volts/Phase/Hertz (each circuit)
Run Amps Comp
LRA Compressor
Total Blwr/Fan Motor Run Amps
Total Blwr/Fan Motor LRA Amps
Duct Static - Min. ( In. Water Column)
Duct Static - Max. ( In. Water Column)
Generator Size Per/Unit - Min. ***
Wire Size (Up to 24 ft.)**
(Suggested)
Circuit Protection
Time Delay Fuse or
HACR Circuit Breaker
Control Voltage
Refrigerant
System Refrigerant Charge
Size (In Inches)
Installed
Weight
*
Models ending with .506 suffix and manufactured with "SIDE AIR DISCHARGE".
For wire lengths over 24 ft. consult the National Electric Code for proper sizing.
**
***
The Manufacturer gives only general guidelines for generator requirements. These generator
requirements come from experiences consumers have with our equipment in field applications.
When sizing the generator, the total electrical power must be taken into consideration. Keep in
mind that generators lose power because of altitude increases above sea level , high outdoor
temperatures and lack of maintenance.
INSTALLATION INSTRUCTIONS
2.6 WIRING DIAGRAM 39726.501 & 39726.506
WHT
G-Y
G-Y
BLK
CIRCUIT
BOARD
T1
K1
COM
6
7
8
T4
NO
NC
T2
ORN
T3
RED
K6
NO
NC
BLK
COM
P6
ORN
BLK
WHT
ORN
ELEC.
BOX
BLKHD
ORN
G-Y
GRY
RED
COMP
WHT
STARTER
START
CAP
RED
WHT
RED
HERM
WHT
C
FAN
WHT
RUN
WHT
CAP
VIO
BLK
VIO
BLK
ELEC.
BOX
BRN
BLKHD
WHT
MOTOR
CAP
GRY
WHT
RUN
BLK
COND. BLOWER
COND. BLOWER
C
CAP
HERM
BRN
GRY
BRN
WHT
RED
START
CAP
COMP
STARTER
39726.501 & 39726.506*
26,000
115 AC / 1 / 60
(Circuit 1 =10.0)
(Circuit 1 = 59.0)
8.5 (Circuit 1)
18.0 (Circuit 1)
0.40
1.20
7.5K
(Circuit 1) No. 10 AWG Copper Conductors)
(Circuit 2) No. 12 AWG Copper Conductors)
(Circuit 1) 25Amp
(Circuit 2) 15Amp
12V DC
R-22
(Circuit 1 = 46.5)
Width
Height
46
18
205 Pounds
10
EVAP. BLOWER
EVAP. BLOWER
MOTOR
COMPRESSOR
R
WHT
WHT
C
WHT
BRN
S
BRN
BLK
RED
VIO
BLK
BLK
VIO
BLK
BLK
EVAP. COIL
EVAP. COIL
BRN
BRN
ORN
GRY
R
MOTOR
COMPRESSOR
C
S
BRN
FIELD WIRING
FIELD WIRING
FACTORY WIRING
= WIRE NUT
= WIRE NUT
3108345.095
3108345.095
(Circuit 2 = 9.8)
(Circuit 2 = 59.0)
(Circuit 2 = 38.5)
Depth
22
OL
BLK
REV.
VALVE
ASM
REV.
REV.
VALVE
ASM
OL

Advertisement

Table of Contents