DoorKing 1812 PLUS Owner's Manual page 47

Residential telephone intercom / access control system
Table of Contents

Advertisement

SYMPTOM
System generates
tone when granting
access to a visitor, but
will not work on
regular phone line.
System will not
answer when called
from the resident's
phone.
System will not
answer when called
from a remote
location.
Electric strike locks on
or gate operator holds
open.
Access code will not
work.
1812-161-E-1-10
POSSIBLE SOLUTION(S)
Switch the wires on the PHON IN terminals.
Using the wrong attention number. Re-program attention number.
Answer incoming call feature is turned off. Turn answer incoming call feature
on.
Number of rings to answer may be programmed too high. Reprogram number
of rings to answer.
Excessive voltage drop on 16 VAC line.
Hold open schedule is enabled. Turn off hold open schedule or reprogram time
zone.
Access code used was programmed under a hold location code. Reprogram
access code into a momentary activation location code.
A hold command was sent to the relay from the resident's phone. Deactivate
the relay using the resident's phone.
Forgetting to press # first.
Access code is time zone restricted and the access code time zone is enabled.
Turn access code time zone off, reprogram time zone boundaries or reprogram
access code without a time zone.