step 10
Hood/trunk pins
The BLUE (H1/6) wire will respond to a negative input with an
instant trigger. It is ideal for hood and trunk pins and will report
on Zone 1. It can also be used with Directed Electronics 506T
Glass Breakage Sensor, as well as other Directed Electronics
single stage sensors.
step 11
Adjusting the shock sensor
n n o o t t e e : : The control module must be mounted in its per-
manent location before adjustments are made.
i i m m p p o o r r t t a a n n t t : : Ensure that the adjustment screw on the con-
trol module is accessible in the permanent location.
The double guard shock sensor is a two stage sensor; with both
warn away trigger and full trigger zones. Adjustment of the
sensor will affect both zones simultaneously. To adjust the sensor,
turn the adjustment screw on the side of the control module.
For a more sensitive setting turn the adjustment screw clockwise
in small increments, testing the sensitivity after each adjustment
until the desired setting is achieved.
For a less setting turn the adjustment screw counter clockwise in
small increments, testing the sensor after each adjustment until
the desired setting is achieved.