Basement/crawl space dehumidifiers 198 pint (saturation), 90 ppd (aham), energy star listed, auto defrosting system, commercial dehumidifier (13 pages)
Page 3
Table of Contents Warranty Registration Safety Notes Identification Electrical Supply Principle of Operation Installation Key Functions Indicator Lights Remote Control Diagram Maintenance Dehumidifier Storage Troubleshooting Water Pump Maintenance and Application Spare Parts Warranty Information...
Page 4
Warranty Registration Congratulations on purchasing a new Sentinel Dehumidifier. Your new dehumidifier comes with an extensive warranty plan. To register, simply fill out and return warranty form provided in the dehumidfier Be sure to note your dehumidifier serial number as you will need it for registration. Safety Notes •...
Page 5
Number: Date of Purchase: For additional questions concerning your dehumidifier, the following options are available: • Contact your installing contractor • E-mail: sales@alorair.com Electrical Supply Power Supply: 115 V, 60 Hz AC, Sing e Phase Outlet Requirement: 3-Prong, GFCI Circuit Protector: 15 Amp 240 Volts AC may cause serious injury from electric shock.
Page 6
Slide compression nut side of hose over the insert on the compression fitting com pletely. Tighten compression nut. Step #3: Plug unit into 15 amp grounded circuit. Key Functions — ALORAIR— ONIOFF DRAIN GPP MODE "ON 1 OFF" Button...
Page 7
"SET" Button This button is used to change the humidity setpoint from 25% to 80%. The dehumidifier also be set at "CO" or Continuous Operation mode to run the dehumidifier continuously. setpoint has 5% increments of each press The dehumidifier will automatically turn on/off when the Relative Humidity Percentage(%)
Page 8
Relative humidity (RH) refers to the moisture content of the atmosphere, expressed as a percentage of the amount of moisture that can be retained by the atmosphere at a given temperature and pressure with condensation. 5. "SET +Drain" if you press the combination button "SET +Drain"...
Page 9
Remote Control Instructions Sentinel Dehumidifiers can be controlled using an optional remote accessory. The Sentinel Remote Control connects to your Sentinel Series Dehumidifier via a 25' CAT 5 cable. The remote control contains an integrated sensor which gives you multiple options for remotely controlling your unit, in addition to monitoring the conditions surrounding the dehumidifier.
Page 10
Sentinel HD35P Diagram Front View Unit Cover Handle Filter Control panel Pump Drain Back View Handle Power cord Unit Cover outlet Gravity Drain A1-A6 Controller Aux. Terminal Terminal...
Page 11
Maintenance Always unplug the unit before doing any maintenance. WARNING: ÜCleaning the machine body Use a soft damp cloth to clean exterior of unit. Do not use any soap or solvents Coil Maintenance • Once per year, clean the coils with an approved coil cleaner. •...
Page 12
Troubleshooting Symptom Cause Solution Power Supply Verify that there is power to the outlet and that the plug is properly installed in outlet The unit is outside the operating Machine Won't Room Temperature Over 1100 temperature range. Modify the room (Display HI) or Below 33.80F conditions so the temperature...
Page 13
Water Pump Maintenance and Application Normal use of water pump 1. Determine whether the forced drainage function is useful When the power is on, press the "Drain" button, the water pump runs normally, the pumping water is normal , there is no vibration and noise, and the water flows smoothly ON/OFF 196ft...
Page 14
For gravity drainage, the dehumidifier should be placed on a plane with a certain height. Pull out the screw tooth rubber plug at the outlet of the water collector of the dehumidifier, and plug in the water pipe The condensate dripping from the coil will be discharged along the water pipe, which can be collected into the water storage container or discharged out of the room (Note: the water pipe should not be higher than the dehumidifier and should be discharged towards the ground) Gravity Drain...
Page 15
19.6 ft Water Lever Switch Internal Hose Pump repair method 1 . Use a Phillips screwdriver to unscrew the five screws on the water pump panel, you can see the fixed state of the water pump. 2. Use a Phillips screwdriver to loosen the two screws of the water pump fixing bracket. 3.
Page 16
Sentinel HD35P spare Parts Sentinel HD35P - Parts Description Part# Remote Control Package(cable+remote) s-108 Main Control Board Display Board s-109 RH/Temperature Sensor s-110 s-601 Motor Complete Fan Assembly s-602 Fan Capacitor s-603 Compressor s-604 Compressor Capacitor s-605 Coil Assembly s-606...
Page 17
Alorair Solutions will not provide in-home service during or after the warranty period. You may be responsible for the shipping charge to bring the product to the manufacturer for service.
Page 19
EMAIL: If you have any questions, please feel free to contact us at 888-990-7469 or visit www.alorai Register your unit for warranty using this link: www.alorair.com/page/Warranty--Warranty-registratio Warranty Registration https://www.alorair.com or scan this barcode to direct you to the warranty registrati...
Need help?
Do you have a question about the Sentinel HD35P and is the answer not in the manual?
Questions and answers