roubleshooting
Reduced spray or no spray
Possible causes
1. Spray nozzle clogged
2. Solution/clean tank empty
3. Solution/clean tank insert clogged
4. Pump needs priming
Deep cleaner won't pick up cleaning solution
Possible causes
1. Tank release latch is not closed properly
2. Poor tool position
3. Collection/dirty tank is full
4. Tool brush worn
5. Excess cleaning solution in vacuum flex hose
6. Incorrect cleaning formula
R
eplacement parts
Item
Part No.
1
203-7151
2
203-7158
3
203-7144
4
203-7169
5
203-7150
6
203-7159
7
203-5014
CLEANING FORMULAS
8
79B9E
9
74R7E
w w w . b i s s e l l . c o m
Other maintenance or service not included in the manual should be performed by an
Part Name
Tough Stain Brush Tool
Solution/Clean Tank
(includes cap and insert assembly)
Collection/Dirty Tank
(includes the airstack and float assembly)
Quick Release Cord Wrap
Vacuum Flex Hose Storage Bracket
(includes screw for assembly)
Vacuum Flex Hose Clip
Bottle Cap & Insert Assembly
473 mL. 2X Concentrate Little Green
Advanced Formula
473 mL. 2X Concentrate Pet Stain & Odor
Advanced Formula
Remedies
1. Clean spray nozzle
2. Check/fill tank
3. Clean insert at bottom of clean/solution tank
4. Gently lift solution/clean tank while depressing
Remedies
1. Lift up the tank release latch and press down
2. Reposition tool on surface, follow
3. Empty collection/dirty tank
4. Replace with new brush
5. Lift hose and point upwards to allow water
6. Use BISSELL Little Green formula only
authorized service representative.
the spray trigger OR gently squeeze solution/
clean tank while depressing spray trigger
firmly to make sure it is in place
recommended cleaning procedures
in hose to flow into the collection/dirty tank
1
2
4
5
7
8
3
6
9