Firmware Version 740 and up
2025-03
List-Magnetik Dipl.-Ing. Heinrich List GmbH
D-70771 Leinfelden-Echterdingen Max-Lang-Str. 56/2
Fon: + 49 (711) 903631-0
Internet: https://www.list-magnetik.com
E-mail: info@list-magnetik.de

Advertisement

loading
Need help?

Need help?

Do you have a question about the FerroPro compact and is the answer not in the manual?

Questions and answers

Summary of Contents for List-Magnetik FerroPro compact

  • Page 1 OPERATION MANUAL MAGNET PERMEABILITY METER FerroPro compact Firmware Version 740 and up 2025-03 List-Magnetik Dipl.-Ing. Heinrich List GmbH D-70771 Leinfelden-Echterdingen Max-Lang-Str. 56/2 Fon: + 49 (711) 903631-0 Internet: https://www.list-magnetik.com E-mail: info@list-magnetik.de...
  • Page 2 Applications for Windows, Android, iOS ...... 22 Lima Connect for Windows .....................22 Lima Connect for Android and iOS ..................22 SCPI Communication Interface ........24 Important Instructions ..........25 Preserve stored Measurements when changing the battery ............25 Changing the probe .......................25 List-Magnetik GmbH EN FerroPro compact 2025-03.doc...
  • Page 3 A calibration standard is supplied with each instrument. The magnetic permeability of a material is usually strongly dependent on the strength and frequency of the magnetizing field. The probe of the FerroPro compact can be adjusted to different excitation field strengths. FerroPro compact can be used to perform standard-compliant permeability measurements according to ASTM A342 test methods 1 and 4, EN 60404-15 method 6 and VG 95578.
  • Page 4 TART • First connect the probe cable to the probe and the instrument. • Switch on FerroPro compact with the red power button. • An automatic zero is performed when the instrument is turned on. During this process, the probe should be away from metal parts and out of a magnetic field.
  • Page 5 = 4 x Pi x 10 m kg FerroPro compact is used for material selection in applications where absolutely non- magnetic materials must be used, such as in the electron microscope, electron or ion spectroscopy, in nuclear magnetic resonance equipment, and in the vicinity of com- pass navigation equipment.
  • Page 6 From a thickness of about 5 mm and an extension of about 2 cm, the measurement is independent of the size. The approximate dependence of sensitivity on thickness is shown in the following diagram. The sensitivity is defined as (µr - 1) / (µr - 1). displayed true List-Magnetik GmbH EN FerroPro compact 2025-03.doc...
  • Page 7 The status bar shows the title of the current menu position and the battery status. The statistics area displays statistics for a series of measurements. If no memory batch is active, the List-Magnetik logo is displayed here. In the center is the measurement display with the current measurement and addi- tional information about it.
  • Page 8 This section allows you to set the language, unit of measure, and other measurement and display parameters, as well as power management settings. Info and System Turn off the unit, view hardware and software status, or perform a factory reset. List-Magnetik GmbH EN FerroPro compact 2025-03.doc...
  • Page 9 The color of the reading is black. If limit values are set, the measured value is displayed in blue if it is below the lower limit value and in red if it is above the upper limit value. List-Magnetik GmbH EN FerroPro compact 2025-03.doc...
  • Page 10 If you have activated a memory batch, the statistics for this memory batch will be displayed in the area above the reading instead of the logo. Actions Overview of the action area in the measurement display. List-Magnetik GmbH EN FerroPro compact 2025-03.doc...
  • Page 11 From the moment of activation, measurements can be stored Special Function Scan Measurement SCAN See separate chapter " Special Measurement Methods ". The jump to the scan measurement is only possible if the peak value measurement / PEAK is switched off. List-Magnetik GmbH EN FerroPro compact 2025-03.doc...
  • Page 12 Memory batch number 4 is active (M4). There are 7 memory batches in total (4/7). A total of 15 values are stored in memory batch 4. Maximum, minimum, average and standard deviation are calculated from these 15 values. The last stored value was 1.010 List-Magnetik GmbH EN FerroPro compact 2025-03.doc...
  • Page 13 Make sure that the measurement type is set to the correct exci- tation field strength. Calibration Standards Provided by List- Magnetik are referenced to 30 kA/m. A detailed explanation follows this overview Back to measurement List-Magnetik GmbH EN FerroPro compact 2025-03.doc...
  • Page 14 If you have not created or activated a memory batch, not all results will be stored. The floppy disk symbol is then not visible during continuous measurement. Actions Overview of the data log management action area. List-Magnetik GmbH EN FerroPro compact 2025-03.doc...
  • Page 15 Approx. 20 measurements per second are performed automatically. The measurement is shown graphically on the display. In the statistics display, the count, minimum, maximum and average values are calculated and displayed. List-Magnetik GmbH EN FerroPro compact 2025-03.doc...
  • Page 16 You can create as many scan memories as you like. The memory batches are given a unique free number and a prefixed “S” Browse through the saved scans. The statistics, short text, and graphical progress curve are displayed Delete the currently displayed scan List-Magnetik GmbH EN FerroPro compact 2025-03.doc...
  • Page 17 The trash can icon deletes the entire series of measurements. The memory batch remains active, however, so that further measurements will be written to this memory batch. If an individual reading is inactive, it can be permanently deleted by clicking the scissors icon. List-Magnetik GmbH EN FerroPro compact 2025-03.doc...
  • Page 18 You can set the automatic shutdown time: 5 minutes, 10 minutes, 30 minutes or "never off" if you do not want the device to turn off automatically. The power save mode switches the brightness back to 10% after 1 minute. List-Magnetik GmbH EN FerroPro compact 2025-03.doc...
  • Page 19 Upper limit value exceeded: measured value red Falling below the lower limit: measured value blue The color change occurs both in the measurement display and in the data log. List-Magnetik GmbH EN FerroPro compact 2025-03.doc...
  • Page 20 Date and time can be set manually or via the PC application Lima Connect. When setting manually, please note the notation xxxx-xx-xx (with hyphens) for the date and xx:xx:xx (with colons) for the time. List-Magnetik GmbH EN FerroPro compact 2025-03.doc...
  • Page 21 The device data shows, for example, the serial number, the firmware version, the current battery voltage and the MAC address for the wireless connection. This data helps in the event of support. Battery voltage must be above 2.8V. Below 2.8V, the unit will automatically shut down. List-Magnetik GmbH EN FerroPro compact 2025-03.doc...
  • Page 22 3x 1.5V AA Mignon. External power supply connectable via USB Approximately 25 hours with battery, unlimited with Operating time: external power source. Dimensions: 150 x 85 x 35 mm Weight: 320 g with batteries List-Magnetik GmbH EN FerroPro compact 2025-03.doc...
  • Page 23 Lima Connect for Android and iOS. Exclusively in these two mobile versions you can manage projects and assign the measuring points on a photo. The measurement results can be statistically evaluated and displayed graphically. The app for Android and iOS is also free. List-Magnetik GmbH EN FerroPro compact 2025-03.doc...
  • Page 24 Android List-Magnetik GmbH EN FerroPro compact 2025-03.doc...
  • Page 25 The SCPI Demo installation package contains: a runtime environment for LabView, a sample application (EXE) for each of the three devices MP-4000, FerroPro compact and MEGA- CHECK DX as well as the sources (SRC) for these three applications. To be able to read and edit the sources, however, a license for LabView is required, which is not included.
  • Page 26 HANGING THE PROBE To replace the measuring probe, switch off the device beforehand. Connect the desired measuring probe to the probe cable, then switch the device on again. List-Magnetik GmbH EN FerroPro compact 2025-03.doc...
  • Page 27 (Permeability and Ferrite content) We provide expert advice and design metrology solutions tailored to your specific needs. Fast calibration and repair service List-Magnetik Dipl.-Ing. Heinrich List GmbH D-70771 Leinfelden-Echterdingen Max-Lang-Str. 56/2 Fon: + 49 (711) 903631-0 Internet: https://www.list-magnetik.com E-mail: info@list-magnetik.de...

This manual is also suitable for: