  • Page 1 OPERATION MANUAL FLUXMETER FLUX-CHECK 250 Firmware Version 740 and up 2025-03 List-Magnetik Dipl.-Ing. Heinrich List GmbH D-70771 Leinfelden-Echterdingen Max-Lang-Str. 56/2 Fon: + 49 (711) 903631-0 Internet: https://www.list-magnetik.com E-mail: info@list-magnetik.de...
  • Page 2: Table Of Contents

    Applications for Windows, Android, iOS ...... 23 Lima Connect for Windows .....................23 Lima Connect for Android and iOS ..................23 SCPI Communication Interface ........25 Important Instructions ..........26 Preserve stored Measurements when changing the battery ............26 Changing the probe .......................26 List-Magnetik GmbH EN FLUX-CHECK 250 2025-03.docx...
  • Page 3: Introduction

    Helmholtz HM-2 torque coil, all types of coils or coil probes can be connected to the instrument. The FLUX-CHECK 250 fluxmeter has a very high input resistance of 33 kΩ, so that the measuring error is negligible when connecting any coil probes, even with high internal resistance.
  • Page 4: Warnings And Hazards

    UIDE • First connect the probe cable to the coil and the instrument. • Switch on the FLUX-CHECK 250 with the red on/off button. • An automatic zero adjustment is performed when the instrument is switched on. There must be no magnet in the coil.
  • Page 5: General Information On Measuring Units

    NFORMATION ON EASURING UNITS Four different values can be determined with the FLUX-CHECK 250 fluxmeter. The four values have different units and are therefore not comparable. These values are included separately in the statistics so that a minimum/maximum/average value can be analyzed.
  • Page 6: Magnetic Flux Density (Fld)

    The flux density can be displayed in A/cm and mT. The factor between A/cm and mT is 1.256 (as a rule of thumb: 4 A/cm ~ 5 mT). Measured magnetic flux density values are displayed in memory and statistics with the abbreviation FLD. List-Magnetik GmbH EN FLUX-CHECK 250 2025-03.docx...
  • Page 7: Display Structure

    The status bar shows the title of the current menu position and the battery status. The statistics area displays statistics for a series of measurements. If no memory batch is active, the List-Magnetik logo is displayed here. In the center is the measurement display with the current measurement and additional information about it.
  • Page 8: Navigation

    This section allows you to set the language, unit of measure, and other measurement and display parameters, as well as power management settings. Info and System Turn off the unit, view hardware and software status, or perform a factory reset. List-Magnetik GmbH EN FLUX-CHECK 250 2025-03.docx...
  • Page 9: Measurement

    Below the reading is an analog bar graph. When limits are set, the bar represents the range between the lower and upper limits. The bar is complete when the value falls below the lower limit or exceeds the upper limit. List-Magnetik GmbH EN FLUX-CHECK 250 2025-03.docx...
  • Page 10 The statistics of this memory batch are displayed in the area above the measurement display as in normal measurement. If you have activated a memory batch, the statistics for this memory batch will be displayed in the area above the reading instead of the logo. List-Magnetik GmbH EN FLUX-CHECK 250 2025-03.docx...
  • Page 11 To activate a memory batch, switch to data log management with this icon "Folder". From the moment of activation, measurements can be stored Special Function Scan Measurement SCAN See separate chapter " Special Measurement Methods ". List-Magnetik GmbH EN FLUX-CHECK 250 2025-03.docx...
  • Page 12 A total of 15 values are stored in this batch 4. Maximum, minimum, average and standard deviation are calculated from these 15 values. The last stored value was 1.718 The measured values are of type FLX (flux measurement in mVs or mWb) List-Magnetik GmbH EN FLUX-CHECK 250 2025-03.docx...
  • Page 13: Memory Management

    M memory batches. If you have not created or activated a memory batch, the floppy disk icon will not be visible during the measurement. Actions Overview of the action area in the data log. List-Magnetik GmbH EN FLUX-CHECK 250 2025-03.docx...
  • Page 14 The additional text entered will be displayed. You can view the individual values by clicking on the navigation icon of the data log. Select a memory batch for immediate use Delete the currently displayed memory batch List-Magnetik GmbH EN FLUX-CHECK 250 2025-03.docx...
  • Page 15: Special Measurement Methods

    ACT indicates the current integrated flux value. MAX and MIN indicate the maximum and minimum values of the pulse curve. The TRG value is the currently set trigger level from Setup / Probe Settings. List-Magnetik GmbH EN FLUX-CHECK 250 2025-03.docx...
  • Page 16 You can create as many scan memories as you like. The memory batches are given a unique free number and a prefixed “S” Browse through the saved scans. The statistics, short text, and graphical progress curve are displayed Delete the currently displayed scan List-Magnetik GmbH EN FLUX-CHECK 250 2025-03.docx...
  • Page 17: Data Log

    The trash can icon deletes the entire series of measurements. The memory batch remains active, however, so that further measurements will be written to this memory batch. If an individual reading is inactive, it can be permanently deleted by clicking the scissors icon. List-Magnetik GmbH EN FLUX-CHECK 250 2025-03.docx...
  • Page 18: Setup

    You can set the automatic shutdown time: 5 minutes, 10 minutes, 30 minutes or "never off" if you do not want the device to turn off automatically. The power save mode switches the brightness back to 10% after 1 minute. List-Magnetik GmbH EN FLUX-CHECK 250 2025-03.docx...
  • Page 19: Probe Settings

    For the magnetic moment, mVs·cm and mWb·cm can be selected, as well as the next smaller unit 10 (micro-). Flux density can be displayed in A/cm and mT. The factor between A/cm and mT is 1.256 (rule of thumb: 4 A/cm ~ 5 mT). List-Magnetik GmbH EN FLUX-CHECK 250 2025-03.docx...
  • Page 20: Parameter

    If "Auto Save" is active (slider to the right, black switch), every measurement is saved. If "Auto Save" is inactive (slider to the left, gray switch), the measurement is only saved when the floppy disk icon is pressed. List-Magnetik GmbH EN FLUX-CHECK 250 2025-03.docx...
  • Page 21: Info And System

    Date and time can be set manually or via the PC application Lima Connect. When setting manually, please note the notation xxxx-xx-xx (with hyphens) for the date and xx:xx:xx (with colons) for the time. List-Magnetik GmbH EN FLUX-CHECK 250 2025-03.docx...
  • Page 22: Delete Memory

    The device data shows, for example, the serial number, the firmware version, the current battery voltage and the MAC address for the wireless connection. This data helps in the event of support. Battery voltage must be above 2.8V. Below 2.8V, the unit will automatically shut down. List-Magnetik GmbH EN FLUX-CHECK 250 2025-03.docx...
  • Page 23: Technical Data

    3x 1.5 V AA Mignon. External power supply can be connected via USB Operating time: approx. 25 hours with battery, unlimited with external power supply Dimensions: 150 x 85 x 35 mm Weight: 320 g with batteries List-Magnetik GmbH EN FLUX-CHECK 250 2025-03.docx...
  • Page 24: Applications For Windows, Android, Ios

    Lima Connect for Android and iOS. Exclusively in these two mobile versions you can manage projects and assign the measuring points on a photo. The measurement results can be statistically evaluated and displayed graphically. The app for Android and iOS is also free. List-Magnetik GmbH EN FLUX-CHECK 250 2025-03.docx...
  • Page 25 Android List-Magnetik GmbH EN FLUX-CHECK 250 2025-03.docx...
  • Page 26: Scpi Communication Interface

    The List-Magnetik instruments MP-4000 (magnetic field measurement), FerroPro com- pact (permeability measurement), MEGA-CHECK DX (coating thickness measure- ment), FERRITE-CHECK 240 (ferrite content measurement) and FLUX-CHECK 250 (fluxmeter) are equipped with an SCPI interface, which allows the instrument to perform remote measurements in line operation and to provide measured values. The connection is made via USB, which also ensures power supply and continuous operation.
  • Page 27: Important Instructions

    HANGING THE PROBE To replace the measuring probe, switch off the device beforehand. Connect the desired measuring probe to the probe cable, then switch the device on again. List-Magnetik GmbH EN FLUX-CHECK 250 2025-03.docx...
  • Page 28 (Permeability and Ferrite content) We provide expert advice and design metrology solutions tailored to your specific needs. Fast calibration and repair service List-Magnetik Dipl.-Ing. Heinrich List GmbH D-70771 Leinfelden-Echterdingen Max-Lang-Str. 56/2 Fon: + 49 (711) 903631-0 Internet: https://www.list-magnetik.com E-mail: info@list-magnetik.de...