Novell OPEN ENTERPRISE SERVER 2.0 SP2 - UPGRADING TO OES-PLANNING AND IMPLEMENTATION GUIDE 12-2009 Implementation Manual page 125

Upgrading to oes—planning and implementation guide
Table of Contents

Advertisement

For example, if the first line in the current script reads
ncpcon unbind
--ncpservername=CLUSTERNAME_POOLNAME_SERVER --ipaddress=192.168.10.10
Modify the third line in the downloaded script to read
ignore_error ncpcon unbind
--ncpservername=CLUSTERNAME_POOLNAME_SERVER --ipaddress=192.168.10.10
3d Remove all of the lines down to the first line you inserted.
3e Click Apply > OK.
4 In iManager > Cluster Options, select the iPrint cluster resource object and click the Details
link.
5 On the Cluster Pool Properties page, click the Preferred Nodes tab and move all of the NetWare
nodes to the Unassigned column.
6 Offline and then online the cluster resource.
7 On the server where the iPrint cluster resource is running, open a terminal and enter the
following commands:
cd /opt/novell/iprint/bin
./iprint_nss_relocate -a admin.fqdn -p password -n NSS/path -l cluster
For example, enter
./iprint_nss_relocate -a cn=admin,o=novell -p novell -n /media/nss/
NSSVOLNAME -l cluster
8 Migrate the iPrint resource to another OES 2 SP2 node in the cluster, then repeat
of the OES 2 SP2 nodes in the cluster have run the
9 Create the Print Manager and Driver Store on the OES cluster.
When choosing the target server, use the IP address of the cluster resource. This specifies
where the driver store and Print Manager database will reside. Begin by using the IP address of
the new resource. This will need to be changed to a DNS name later by editing the
When you receive a certificate management error, allow the error and proceed.
While you are creating the Print Manager, the lower dialog box indicates where the Print
Manager will be located. Specify the IP address of the cluster resource. This changes later to a
DNS name.
The iPrint service doesn't "know" that it's running on a cluster because the script creates a
symbolic link. If the link exists, you know that the service is clustered.
10 After you create the Print Manager and Driver Store, modify the
and
conf/ipsmd.conf
For example:
DSServer1 replicaServer
DSServer2 replicaServer
DSServer3 replicaServer
11 Remove the pound sign (#) from the following two lines in the load script:
exit_on_error rcnovell-idsd start
exit_on_error rcnovell-ipsmd start
to have multiple DSServer values.
idsd.conf
iprint_nss_relocate
/etc/opt/novell/iprint/
Step 7
until all
script.
file.
.conf
Examples 125

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OPEN ENTERPRISE SERVER 2.0 SP2 - UPGRADING TO OES-PLANNING AND IMPLEMENTATION GUIDE 12-2009 and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Open enterprise server 2.0 sp2

Table of Contents