Page 1
TE SERIES EQUIPMENT STANDS *Please Note: This manual is intended for use with the above referenced equipment manufactured after October 2024. Traulsen’s equipment stands are solely intended for use with cooking equipment. To obtain a copy of the correct Owner’s Manual to support the same products manufactured prior to this date, please contact Traulsen Service at (800) 825-8220.
Page 2
READING THE SERIAL TAG • Serial = The permanent ID# of your Traulsen unit • Model = The model # of your Traulsen unit • Volts = Voltage •...
Page 3
There is a five (5) day limit to file freight damage with the carrier. Under no condition may a damaged unit be returned to Traulsen without first obtaining written permission (return authorization). You may contact Hobart/Traulsen customer care at 800-333- NOTE: Traulsen does not recommend laying the unit on its 7447 to request a return.
Page 4
The most important thing you can do to ensure a long, current protector in circuit (see amperage requirements reliable service life for your Traulsen is to regularly clean on the unit’s serial tag). the condenser coil and or filter if provided.
Page 5
VII. MICROPROCESSOR CONTROL V. c) CLEANING THE CABINET SURFACE Your new equipment stand is equipped with a digital WARNING: DISCONNECT ELECTRICAL POWER SUPPLY BEFORE control, which precisely regulates operation. It is supplied CLEANING ANY PARTS OF THE UNIT. from the factory completely ready for use. Exterior stainless steel should be cleaned with warm water, mild soap and a soft cloth.
Page 6
VII. c) INITIATING A DEFROST CONT’D VII. c) INITIATING A DEFROST Caution: if DFM = NON or C-H = HEA all defrost functions Automatic defrost: are inhibited; if DFT = 0, automatic defrost functions are Defrost starts automatically as soon as the time set with excluded.
Page 7
VII. e) TECHNICAL DATA CONT’D RANGE DESCRIPTION -58..SPH Minimum limit for SP setting. SPL...180° Maximum limit for SP setting. SPL... SPH Setpoint (value to be maintained in the room). REF; HEA Refrigerating (REF) or Heating (HEA) control mode. 1...10° Thermostat OFF -> ON differential. 0...10°...
Page 8
RANGE DESCRIPTION OFF; ELE; Defrost type OFF: off cycle defrost (Compressor and Heater OFF). ELE: electric defrost (Compressor OFF and Heater ON). GAS: hot gas defrost (Compressor and Heater ON). OFF; Defrost start optimization OFF : no optimization. LO : defrost waits until the compressor cut-out. HI : defrost waits until the compressor cut-in.
Page 9
RANGE DESCRIPTION 0...52 weeks Condenser periodic cleaning. When the compressor operation time, expressed in weeks, matches the ACC value programmed, “CL” flashes in the display. With ACC=0 the condenser cleaning warning is disabled and CND disappears from Info Menu. IISM NON;...
Page 10
RANGE DESCRIPTION OPN; CLS Light activation (only with LSM=ECO or LSM=DIx). OPN : lights on with DIx open or ECO mode deactivated. CLS : lights on with DIx closed or ECO mode activated. 0…600 sec Activation time of OA1 0…600 sec Pause between OA1 activation NON;...
Page 11
VII. f) COMPONENTS & WIRING DIAGRAM Indications: Thermostat output Fan output Defrost output Activation of 2 parameter set Alarm Manual activation / Increase button Exit / Stand-by button Refrigerator Models -10-...
Page 12
SIZE DWG. NO. REV. DIMENSIONAL, MATERIAL OR PERFORMANCE CHARACTERISTICS OF SUCH PARTS AFTER 379-60604-00 APPROVAL BY TRAULSEN & CO. INC. GROUP OF VENDOR SAMPLES UNLESS AUTHORIZED IN OPTION DO NOT SCALE DRAWING WRITING BY TRAULSEN & CO. INC. NO SCALE...
Page 13
Is the fuse OK or circuit breaker on? Is the condenser coil clean? Is the power switch on? If after checking the above items and the unit is still not operating properly, please contact an authorized Traulsen service agent: 4401 Blue Mound Road Fort Worth, TX 76106 (800) 825-8220.
Page 14
IX. b) SPARE PARTS INFORMATION To purchase replacement parts or to speak to service support for Traulsen units please contact our Ft. Worth facility by phone at 800-825-8220 or fax to 817-740-6748 (parts) or 817-740-6757 (service). Note: When calling for spare parts or service support, please make sure you have model and serial number of unit available.
Need help?
Do you have a question about the TE Series and is the answer not in the manual?