Page 2
User’s Manual. Before performing a test for the first time, be sure to consult the User’s Manual regarding how to set up and use your CoaguChek XS meter. Preparing to test and testing Preparing to test...
Page 3
Prepare the lancing device by inserting a fresh lancet. Do not prick your finger until asked to do so. The CoaguChek XS Softclix lancing device is intended only for patient self-monitoring by a single person. It must not be used to collect blood in a...
Page 4
Preparing to test and testing Testing 28:88 18:88 code error Wash your hands with soap and warm water. Dry them thoroughly. Residues of water on the skin can dilute the drop of blood and so produce false results. WARNING Place the meter on a level, vibration-free surface or hold it in your hand so it is roughly horizontal.
Page 5
Preparing to test and testing 11:23 The flashing test strip symbol prompts you to insert a test strip. Remove a test strip from its container. Close the container again with the stopper NOTICE immediately after removing the test strip. Leaving the container open for a longer period of time may damage the strip and lead to error messages.
Page 6
The CoaguChek XS Softclix lancing device is intended only for patient self-monitoring by a single person. It must not be used to collect blood in a...
Page 7
Preparing to test and testing Now prick the side of a fingertip with the lancing device. Stroke the lanced finger until a drop of blood is formed. Do not press or squeeze the finger. CAUTION Apply the first drop of blood from the finger. Apply the blood directly from the finger to the semicircular, transparent sample application area of the test strip.
Page 8
Preparing to test and testing 11:27 11:28 11:29 When you have applied enough blood, the blood drop symbol disappears and measurement starts. Do not add more blood. Do not touch the test strip until the result is displayed. Following a successful outcome of the automatic quality con- trol check (“QC”...
Page 9
Display information and symbols Display information and symbols The following symbols may appear in the display. Please note: This list is not complete. A complete list of display messages and symbols is provided in the User’s Manual. Symbol Meaning Battery status: •...
Page 10
Display information and symbols Symbol Meaning Results are displayed as a Quick percentage value. Results are displayed in seconds. Results are displayed in INR (International Normalized Ratio) units. Result for this blood test is flagged with a “c” due to a low haematocrit value or wet hands. Result is above the chosen therapeutic range (only with INR as unit) Result is below the chosen therapeutic range...
Page 11
Display information and symbols Symbol Meaning Room or meter temperature is outside the acceptable range. Test strip guide cover is open.
Page 12
COAGUCHEK and SOFTCLIX are trademarks of Roche. Roche Diagnostics GmbH Sandhofer Strasse 116 68305 Mannheim, Germany www.roche.com www.coaguchek.com...