The unit will not operate at all.
•
Upper body (neck to lower back) massage
•
Lower body (calves to seat) massage
•
Arm massage
Sometimes the power won't turn on when
again when a massage has finished.
The unit has been damaged.
The power cord or power plug is abnormally hot.
Warning
•
Do not attempt to repair, disassemble or modify the unit.
Failure to observe this precaution may result in fire or injury due to malfunctioning.
Caution
•
Unplug the power plug immediately and contact a customer service center to arrange for repairs if the unit ceases to
function or is otherwise not working properly.
Failure to observe this precaution may result in electric shock or fire.
SPECIFICATIONS
Power supply
Power consumption
Massage area (Up-Down)
Massage area (Left-Right)
Massage area (Forward-back) Projected amount of massage head (Intensity adjustable)
Massage speed
Lateral/Vertical Travel
Massage width
Air Pressure (Calf)
Reclining angle
Automatic Shut-off
When not reclined
(H × W × D)
When reclined
(H × W × D)
Weight of Unit
Dimension of box (H × W × D)
Weight in box
Maximum user weight
Minimum distance from wall
Problem
is pressed
AC 120 V 60 Hz
195 W
Approx. 30 in. (76 cm) (The massage heads move a total of approx. 26 in. (65 cm))
Distance between massage heads during operation (massage width adjustable)
Neck, Shoulder, Back, Lower back: Approx. 3 – 8 in. (7 – 21 cm)
Approx. 4 in. (10 cm)
Tap: Approx. 250 – 450 cycles/minute (single side)
Full roll: Approx. 26 – 92 seconds (both ways)
Other than the above: approx. 6 – 50 cycles/minute
Lateral travel: Approx. 1.5 in. (3.8 cm) left-right auto return
Vertical travel (Long): Approx. 30 in. (76 cm) up-down auto return
Vertical travel (Short): Approx. 4 in. (10 cm) up-down auto return
Full roll, Vertical Movement: Approx. 3 – 7 in. (7 – 18 cm)
Other than the above: Same as massage area (left-right)
5: Approx. 32 kPa
4: Approx. 30 kPa
3: Approx. 25 kPa
2: Approx. 19 kPa
1: Approx. 8 kPa
* It may vary with the area slightly.
Backrest: Approx 120˚ – 170˚
Legrest: Approx 0˚ – 85˚
Automatically turns off after approx. 15 minutes (approx. 5 minutes for the quick massage)
Approx. 47.2 × 33.1 × 50 in. (120 × 84 × 127 cm)
Approx. 28.3 × 33.1 × 76.8 in. (72 × 84 × 195 cm)
Approx. 181 lbs. (82 kg)
Approx. 28.3 × 30.7 × 65.4 in. (72 × 78 × 166 cm)
Approx. 216 lbs. (98 kg)
Approx. 264 lbs (120 kg)
15.7 in. (40 cm)
Cause and Remedy
•
The power cord has been disconnected. (See page 16)
•
The power switch on the unit has not been turned on.
•
A Pre-Program button or Manual Operation button hasn't
been pressed after pressing
Approximately 5 seconds are required for program termination
after a massage finishes. Wait at least 5 seconds once all
movement has stopped before pressing
Stop using the unit immediately.
Stop using the unit immediately.
.
.
48
Need help?
Do you have a question about the EP30007 - Real Pro ULTRATM and is the answer not in the manual?
Questions and answers
Control won't turn on. Any reset?
To reset the Panasonic EP30007 - Real Pro ULTRATM control that won't turn on, follow these steps:
1. Ensure the power cord is connected: Verify that the power cord is properly plugged in.
2. Turn on the power switch: Make sure the unit's power switch is turned on.
3. Wait 5 seconds after a massage finishes: If the control doesn’t respond after a massage, wait at least 5 seconds once all movement has stopped before pressing the button again.
If the issue persists, stop using the unit and inspect the power cord and plug for damage. If needed, contact a qualified technician.
This answer is automatically generated