Canarm CEPD140-3 Operation Instructions And Parts Manual

Ultra quiet ceiling exhaust fan

Advertisement

Quick Links

CEPD140-3
ULTRA QUIET CEILING
EXHAUST FAN
OPERATION INSTRUCTIONS AND PARTS MANUAL
PLEASE READ AND SAVE THESE INSTRUCTIONS
OPERATION INSTRUCTIONS AND PARTS MANUAL
PLEASE READ AND SAVE THESE INSTRUCTIONS
MODELS: CEPD140-3
The purpose of this manual is to aid in the proper installation and operation of the CEPD140-3 ceiling exhaust fan. These instructions
are intended to supplement good general practices and are not intended to overwrite local codes and ordinances.
IT IS THE RESPONSIBILITY OF THE PURCHASER TO ENSURE THAT THE INSTALLATION AND MAINTENANCE OF THIS
EQUIPMENT IS HANDLED BY QUALIFIED PERSONNEL.
Inspect all shipments carefully for damage. THE RECEIVER MUST NOTE ANY DAMAGE ON THE CARRIER'S BILL OF LADING AND
FILE A CLAIM IMMEDIATELY WITH THE FREIGHT COMPANY.
GENERAL SAFETY
1.
Use this unit only in the manner intended by the manufacturer. If you have
questions, contact the manufacturer at the address or telephone number listed in
the warranty.
2.
Before servicing or cleaning unit, switch power off at service panel and lock the
service disconnecting means to prevent power from being switching on
accidentally. When the service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the service panel.
3.
Installation work and electrical wiring must be done by a qualified person(s) in
accordance with all applicable codes and standards, including fire-rated
construction codes and standards.
4.
Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to
prevent backdrafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the
National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
5.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6.
Ducted fans must always be vented to the outdoors.
7.
Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.
8.
This unit must be grounded.
9.
For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
10.
This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up.
11.
To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
12.
Please read specification label on product for further information and requirements.
13.
Do not use in a cooking area.
14.
WARNING: To Reduce The Risk Of Fire Or Electric Shock, Do Not Use This Fan With Any Solid-State Speed Control Device.
15.
The fan must not be installed in a ceiling thermally insulated to a value greater than R40.
16.
Please follow all applicable national, state/provincial and local codes. All of them will supersede this manual.
17.
Failure to follow the safety instructions in this manual may cause serious injury or death due to electrical shock or high
speed rotating parts.
CLEANING AND MAINTENANCE
For quiet and efficient operation, long life, and attractive appearance - lower or remove grille and vacuum interior of unit with the dusting
brush attachment.
The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the
motor with the exact service motor. The impeller should also be replaced.
M-CEPD140-3 04/25
Page 1 of 6

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CEPD140-3 and is the answer not in the manual?

Questions and answers

Summary of Contents for Canarm CEPD140-3

  • Page 1 MODELS: CEPD140-3 The purpose of this manual is to aid in the proper installation and operation of the CEPD140-3 ceiling exhaust fan. These instructions are intended to supplement good general practices and are not intended to overwrite local codes and ordinances.
  • Page 2: Operation

    (with built-in over Fan Housing.) damper) POWER HOUSING CABLE* Keep duct runs short Seal gaps around Housing. ROUND DUCT* WALL CAP* Seal duct (with built-in ROUND Purchase joints with damper) ELBOW(S) * tape. separately M-CEPD140-3 04/25 Page 2 of 6...
  • Page 3: Electrical Wiring Connection

    Refer to the wiring diagram, and connect the wires as shown. BLACK (BLK) WHITE (WHT) GROUND (GRD) BROWN (BRN) SWITCH I WIRE UNIT SWITCH 1 PANEL SWITCH II RECEPTACLE SWITCH 2 SWITCH BOX POWER SUPPLY 120V AC M-CEPD140-3 04/25 Page 3 of 6...
  • Page 4: Grille Installation

    WARRANTY CANARM Ltd. warrants every new fan to be free of defects in material and workmanship to the extent that, within a period of one year from the date of purchase CANARM Ltd. shall either repair or replace at CANARM’s option, any unit or part thereof, returned freight prepaid and found to be defective.
  • Page 5 MODÈLES: CEPD140-3 Ce manuel a pour objectif de fournir un guide pour l'installation et l'utilisation correcte du ventilateur d'extraction de plafond CEPD140-3. Ces instructions sont destinées à compléter les bonnes pratiques générales et ne sont pas destinées à remplacer les normes et codes locaux.
  • Page 6: Opération

    SÉRIE CEPD140-3 VENTILATEUR D'EXTRACTION DE PLAFOND ULTRA SILENCIEUX OPÉRATION Consultez la section Connexion du câblage électrique pour obtenir des détails sur le câblage et les commutateurs. Le boîtier de commande, situé à l'intérieur du boîtier du ventilateur, dispose de trois réglages: Le bouton de faible débit d'air permet de régler le débit d'air inférieur de 30 CFM jusqu'au débit d'air de la vitesse élevée du...
  • Page 7: Instructions De Montage

    SÉRIE CEPD140-3 VENTILATEUR D'EXTRACTION DE PLAFOND ULTRA SILENCIEUX INSTRUCTIONS DE MONTAGE barre de suspension 1. Des barres de suspension coulissantes ont été fournies, qui permettent au boîtier d'être positionné avec précision n'importe où entre le cadre. Les barres s'étendent jusqu'à 24 pouces et peuvent être utilisées sur tous les types de charpente : poutrelles en I, solives...
  • Page 8: Installation De La Grille

    CANARM LTD. Garantie que chaque nouveau ventilateur est exempt de défauts matériels et de fabrication dans la mesure où, dans un délai d’un an à compter de la date d’achat, CANARM Ltd. réparera ou remplacera, au choix de Canarm, toute unité ou pièce de celle-ci, retourné...

Table of Contents