Canarm CNPD100-3 Operation Instructions And Parts Manual

Ultra quiet compact exhaust fans

Advertisement

Available languages

Available languages

Quick Links

CNPD100-3
ULTRA QUIET COMPACT
EXHAUST FANS
OPERATION INSTRUCTIONS AND PARTS MANUAL
PLEASE READ AND SAVE THESE INSTRUCTIONS
OPERATION INSTRUCTIONS AND PARTS MANUAL
PLEASE READ AND SAVE THESE INSTRUCTIONS
MODELS: CNPD100-3
The purpose of this manual is to aid in the proper installation and operation of the CNPD100-3 exhaust fan. These instructions are
intended to supplement good general practices and are not intended to overwrite local codes and ordinances.
IT IS THE RESPONSIBILITY OF THE PURCHASER TO ENSURE THAT THE INSTALLATION AND MAINTENANCE OF THIS
EQUIPMENT IS HANDLED BY QUALIFIED PERSONNEL.
Inspect all shipments carefully for damage. THE RECEIVER MUST NOTE ANY DAMAGE ON THE CARRIER'S BILL OF LADING AND
FILE A CLAIM IMMEDIATELY WITH THE FREIGHT COMPANY.
GENERAL SAFETY
1.
Use this unit only in the manner intended by the manufacturer. If you have questions,
contact the manufacturer at the address or telephone number listed in the warranty.
2.
Before servicing or cleaning unit, switch power off at service panel and lock the service
disconnecting means to prevent power from being switching on accidentally. When the
service disconnecting means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3.
Installation work and electrical wiring must be done by a qualified person(s) in accordance
with all applicable codes and standards, including fire-rated construction codes and
standards.
4.
Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to
prevent backdrafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the
National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
5.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6.
Ducted fans must always be vented to the outdoors.
7.
Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.
8.
This unit must be grounded.
9.
For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
10.
This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up.
11.
To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
12.
Please read specification label on product for further information and requirements.
Please follow all applicable national, state/provincial and local codes. All of them will supersede this manual.
13.
14.
Failure to follow the safety instructions in this manual may cause serious injury or death due to electrical shock or high
speed rotating parts.
CLEANING AND MAINTENANCE
For quiet and efficient operation, long life, and attractive appearance - lower or remove grille and vacuum interior of unit with the dusting
brush attachment.
M-CNPD100-3 11/24
Page 1 of 6

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CNPD100-3 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Canarm CNPD100-3

  • Page 1 PLEASE READ AND SAVE THESE INSTRUCTIONS MODELS: CNPD100-3 The purpose of this manual is to aid in the proper installation and operation of the CNPD100-3 exhaust fan. These instructions are intended to supplement good general practices and are not intended to overwrite local codes and ordinances.
  • Page 2: Operation

    TYPES OF TYPICAL INSTALLATIONS 1. Housing mounted to I-joists - start at Assembly Instructions 1. 2. Housing mounted to joists - start at Assembly Instructions 1. 3. Housing mounted to truss - start at Assembly Instructions 2. M-CNPD100-3 11/24 Page 2 of 6...
  • Page 3 4. Install duct and blower assembly. Hole a. Install duct from the inside of the housing. Fix. the duct by the tab. b. Attach the blower assembly to the housing by 3 screws. Hole Hole M-CNPD100-3 11/24 Page 3 of 6...
  • Page 4: Electrical Wiring Connection

    To attach the grille assembly to the fan housing. Pinch the grille springs on the sides of the grille assembly, and position the grille into the housing with the grille springs in the appropriate slots. Push the grille assembly towards the ceiling to secure. M-CNPD100-3 11/24 Page 4 of 6...
  • Page 5: Service Parts

    WARRANTY CANARM Ltd. warrants every new fan to be free of defects in material and workmanship to the extent that, within a period of one year from the date of purchase CANARM Ltd. shall either repair or replace at CANARM’s option, any unit or part thereof, returned freight prepaid and found to be defective.
  • Page 6: Sécurité Générale

    MODÈLES: CNPD100-3 Ce manuel a pour objectif de fournir un guide pour l'installation et l'utilisation correcte du ventilateur d'extraction CNPD100-3. Ces instructions sont destinées à compléter les bonnes pratiques générales et ne sont pas destinées à remplacer les normes et codes locaux.
  • Page 7: Opération

    1. Boîtier monté sur des solives en I - commencer par la section Instructions de Montage 1. 2. Boîtier monté sur des solives - commencer par la section Instructions de Montage 1. 3. Boîtier monté sur une ferme - commencer par la section Instructions de Montage 2. M-CNPD100-3 11/24 Page 2 de 6...
  • Page 8: Instructions De Montage

    4. Installer l’ensemble conduit et ventilateur. Trou a. Installer le conduit depuis l'intérieur du boîtier. Fixer le conduit à l'aide de la languette. b. Fixez l’ensemble du ventilateur au boîtier à l’aide de 3 vis. Trou Trou M-CNPD100-3 11/24 Page 3 de 6...
  • Page 9: Installation De La Grille

    Poussez l'ensemble de la grille vers le plafond pour le fixer. M-CNPD100-3 11/24 Page 4 de 6...
  • Page 10: Pièces De Rechange

    CANARM LTD. Garantie que chaque nouveau ventilateur est exempt de défauts matériels et de fabrication dans la mesure où, dans un délai d’un an à compter de la date d’achat, CANARM Ltd. réparera ou remplacera, au choix de Canarm, toute unité ou pièce de celle-ci, retourné...

Table of Contents