Parker 6040 Instructions For Use Manual

Parker 6040 Instructions For Use Manual

Flowmeter and eavs

Advertisement

Quick Links

Porter Midas™ Flowmeter and eAVS
Instructions for Use and Installation Guide
FM-1496, Rev. R
25SEP2024
Parker Hannifin Corporation
Porter
245 Township Line Road
Hatfield, PA 19440 USA
Office 215-723-4000
www.PorterInstrument.com/Midas

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 6040 and is the answer not in the manual?

Questions and answers

Summarization of Contents

Device Information
Intended Use
Explains the primary purpose and application of the Midas Flowmeter and eAVS.
Available Models
Details the various Midas Flowmeter models and their configurations.
User Interface Overview
Device Physical Interface
Identifies and describes the physical components of the Midas Flowmeter.
Touchscreen Interface Details
Touchscreen Navigation and Controls
Details the functions and labels of buttons and displays on the touchscreen.
Setting Screen Interface
Gas and Rate Configuration Settings
Explains how to configure gas percentages and flow rates on the device.
System and Configuration Options
Covers settings like Bluetooth, PIN activation, and language selection.
Logs Screen Interface
Accessing Procedure Logs
Details the log entries for procedures, including open/close details.
System and Notification Log Details
Describes system log entries, including events and notifications.
Scavenger Screen Interface
Scavenger Flow Adjustment and Monitoring
Explains how to adjust and monitor the scavenger flow rate.
Gas Remaining Screen Interface
Tracking Dispensed Gas Volumes
Shows how to view dispensed gas volumes and estimated remaining amounts.
Device Principles of Operation
Midas Flowmeter Functionality
Describes the Midas Flowmeter's function as a gas mixing and delivery device.
eAVS Functionality
Explains the eAVS's role in scavenging nitrous oxide.
Device Use and Patient Population
Intended Use and Patient Criteria
Defines the intended patient population and use cases for the device.
Safety Features
Core Safety Mechanisms and Failsafes
Describes safety features like O2 failsafe, DISS fittings, and check valves.
Onboard Diagnostics and PIN Security
System Self-Checks and Notifications
Details the flowmeter's onboard diagnostics and notification system.
Nitrous Oxide PIN Activation
Explains the PIN activation for controlling N2O flow.
Technical Specifications
eAVS Specifications
Lists dimensions, electrical, environmental, and connection specs for the eAVS.
Flow Meter Specifications
Flowmeter Physical Dimensions and Weight
Provides physical specifications for the Midas Flowmeter and its components.
Gas Supply and Electrical Specifications
Details gas inlet/outlet connections, pressure, and electrical requirements.
Installation Instructions
Compatible Vacuum Controllers
Shows compatible vacuum controllers, including the eAVS.
Connecting the Vacuum Controller
Step-by-step guide for connecting the eAVS to the flowmeter.
Connecting the Bag Tee
Bag Tee Installation Steps
Instructions for connecting the bag tee to the flowmeter and breathing circuit.
Mounting Accessories
Flowmeter Mounting Options Overview
Displays various accessories for mounting the flowmeter.
Mounting the Midas Flowmeter
Wall Mount Installation Procedure
Detailed steps for mounting the flowmeter using a wall arm.
Flowmeter Mounting Procedures
Securing to Wall Mount
Final steps for attaching the flowmeter to the wall mount.
Mounting on Stands and Carts
Instructions for mounting the flowmeter on carts and stands.
Under Counter Installation
Under Counter Mounting Preparation
Steps for marking, drilling, and preparing for under-counter mounting.
Under Counter Mount Installation Steps
Securing Under Counter Components
Instructions for mounting the Bag Tee and eAVS under a counter.
Connecting Supply Lines
Gas and Power Cable Connections
Details connecting gas supply lines and power to the flowmeter.
Instructions for Use
Initial Setup Procedure
Steps for initial setup before operating the flowmeter.
Flowmeter Configurations
Gas Percentage and Rate Settings
Guide to setting gas percentages and flow rates on the device.
Configuration Settings
Bluetooth and Language Settings
How to configure Bluetooth and select the display language.
Nitrous Oxide PIN Activation Setup
Steps for enabling and setting the N2O PIN.
Date and Time Settings
Date and Time Configuration
Instructions for setting the device's date and time format.
Operating the Flowmeter
Powering On and Starting Procedure
Steps to turn on the device and initiate a procedure.
Operating the Flowmeter (Continued)
O2 Recovery and Procedure Termination
Details on O2 recovery, flush, and stopping the procedure.
PIN Configuration
Setting and Changing the N2O PIN
Guides on setting up and modifying the N2O PIN.
iPad Configuration and Pairing
iPad Pairing Process
Steps for connecting the iPad to the Midas Flowmeter via Bluetooth.
Flowmeter vs. iPad Screen Differences
iPad App Functionality Details
Highlights differences and capabilities of the iPad app vs. the flowmeter screen.
Feature Differences: Flowmeter vs. iPad App
Flowmeter-Exclusive Settings
Clarifies which settings are exclusive to the flowmeter screen.
Bluetooth Connectivity and Compatibility
BLE Connection Specifications and Range
Information on Bluetooth version, frequency, security, and range.
Maintenance and Pre-Checks
Maintenance Overview and Warnings
Overview of maintenance requirements, pre-checks, and warnings.
Pre-Check Procedures
Detailed steps for daily and monthly pre-checks.
Pre-Check Procedures (Continued)
Gas Supply Failure and Delivery Tests
Tests for N2O failure, flow delivery, percentage accuracy, and O2 flush.
Pre-Check Procedures (Continued)
eAVS and Valve Functionality Tests
Tests for eAVS, non-rebreathing valve, and emergency air intake valve.
Troubleshooting: Notifications and Alerts
Resolving Device Notifications
Lists common device notifications and their recommended actions.
Troubleshooting: Alerts and Errors
Communication and Memory Error Resolution
Guides on resolving communication failures and memory errors.
Alert Resolution and Default Restorations
Guides on resolving alerts like Bluetooth errors and default restorations.
Frequently Asked Questions (FAQs)
Common Operational FAQs
Answers common questions about turning on/off, PIN reset, and O2 features.
App Updates and Data Export FAQs
Information on updating the remote app and exporting logs.
Electromagnetic Compatibility
EMC Compliance Testing Summary
Details emission and immunity testing compliance with IEC 60601-1-2.
Symbols Glossary
Standard Device Symbols Explained
Explains common symbols used on the device and in the manual.
Symbols Glossary (Continued)
Additional Safety and Usage Symbols
Defines more symbols related to handling, safety, and electrical properties.
End User License Agreement
EULA Terms and Conditions Overview
Outlines the terms of use for the software and information.
End User License Agreement (Continued)
Prohibited Uses and Warranty Disclaimer
Lists prohibited actions and disclaims warranties for the software.
Font Licensing
Adobe Font License Details
Details the license used for the 'Source' font.
Warranty Information
Warranty Terms and Limitations
Explains the warranty period, coverage, and exclusions.

Table of Contents