TYAN TIGER I7505 Manual page 44

Table of Contents

Advertisement

Rebuilding A Mirrored Array
The Rebuild Array <5> Menu option is necessary to recover from an error in a mirrored disk array.
You will receive an error message when booting your system.
NOTE: Drives MUST be replaced if they contain any physical errors.
Follow these steps BEFORE using the Rebuild Array menu option:
1.
On bootup, the Startup BIOS will display an error message identifying which drive has failed.
2.
Press <Ctrl-F> keys to enter FastBuild Main Menu.
3.
Select submenu Define Array <3>.
4.
Select the failed array and identify the Channel and ID of the failed drive.
5.
Power off and physically remove the failed drive.
6.
Replace the drive with an identical model.
7.
Reboot the system and enter the FastBuild Main Menu.
8.
Select the <5> Rebuild Array option. The following screen will appear.
FastBuild (tm) Utility 2.xx (c) 2002-2005 Promise Technology, Inc.
Array No
Array 1
Array 2
Array 3
Array 4
9.
Highlight the array whose Status is "Critical".
10. Press [Enter]. The following screen will then appear (see next page).
[ Rebuild Array Menu ]
RAID Mode
Mirror
——
——
——
[↑] Up [↓] Down
http://www.TYAN.com
Total Drv
Capacity(MB)
2
——
——
——
[ Keys Available ]
[ESC] Exit
[Enter] Select
44
Status
16126
Critical
——
——
——
——
——
——

Advertisement

Table of Contents
loading

This manual is also suitable for:

S2668

Table of Contents