Comfort Glow CSNPT Owner's Operation And Installation Manual page 10

(vent-free) gas stove heater
Table of Contents

Advertisement

INSTALLATION
10
Checking Gas Connections (Cont.)
Installing Rod and Screen
INSTALLATION
Continued
Pressure Testing Heater Gas Connections
1. Open equipment shutoff valve (see Figure 9, page 9).
2. Open main gas valve located on or near gas meter for natural
gas or open propane.LP supply tank valve.
3. Make sure control knob of heater is in the OFF position.
4. Check all joints from equipment shutoff valve to control valve
(see Figure 10 or 11). Apply noncorrosive leak detection fluid
to gas joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Light heater (see Operating Heater, page 11). Check all other
internal joints for leaks.
7. Turn off heater (see To Turn Off Gas to Appliance, page 11).
Control Valve Location
Figure 10 - Checking Gas Joints on Propane/LP Gas Unit
Control Valve Location
Figure 11 - Checking Gas Joints on Natural Gas Unit
For more information, visit www.desatech.com
For more information, visit www.desatech.com
Equipment
Shutoff Valve
Propane/LP
Supply Tank
Equipment
Shutoff Valve
Gas Meter
INSTALLING ROD AND SCREEN
1. Insert rod through small rings located at top of screen (see
Figure 12).
2. From back of stove, insert rod into hole located inside right
front of stove as shown in Figure 13.
3. Slip left side of rod down into slot on inside left front of stove
(see Figure 13).
Rod
Figure 12 - Assembling Rod and Screen
Slot on Inside Left
Front of Stove
Figure 13 - Installing Screen Into Stove (View From Back of
Stove)
Rings
Rod with Screen
Assembled
Hole on Inside Right
Front of Stove
111487-01A

Advertisement

Table of Contents
loading

This manual is also suitable for:

CsbntCspbntCspbptCspintCspipt

Table of Contents