MANUAL
INSPECTING
BURNER
Check pilot flame pattern and burner flame
pattern often.
PILOT FLAME
PATTERN
Figure 26 shows a correct pilot flame pat-
tern. Figure 27 shows an incorrect pilot
flame pattern. The incorrect pilot flame is
not touching the thermocouple.
This will
cause the thermocouple to cool. When the
thermocouple
cools, the heater will shut
down.
If pilot flame pattern is incorrect,
as shown
in Figure 27
• turn heater
off (see To Turn Off Gas to
Appliance,
page 14)
seeTroubleshooting,
pagesl6throughl8
Pilot Burner
Thermocouple
Figure 26 - Correct Pilot Flame Pattern
PilotBurner
Thermocouple
BURNER
FLAME PATTERN
Figure 28 shows a correct burner flame
pattern. Figure 29 shows an incorrect burner
flame pattern. The incorrect burner flame
pattern shows yellow tipping of the flame. It
also shows the flame higher than one inch
above the log.
Note: When using the heater the first time,
the flame will be yellow for approximately
one hour until the log cures.
Ak WARNING: If yellow tipping
occurs, your heater could pro-
duce Increased levels of carbon
monoxide.
If burner flame pat-
tern shows yenowtipping,
follow
instructions
at bottom
of this
page.
NOTICE: Do not mistake orange
flames with yellow tipping. Dirt
or other fine particles enter the
heater and burn causing
brief
patches of orange flame.
If burner flame pattern is incorrect, as shown
in Figure 29
• turn heater
off (see To Turn OffGas
to
Appliance,
page 14)
• seeTroubleshooting,
pagesl6throughl8
Top of Flame About
One Inch Above Logs
CLEANING
AND
MAINTENANCE
_lb WARNING:
Turn off heater
and let cool before cleaning.
_k
CAUTION:
You must keep
control areas, burner, and circu-
lating air passageways of heater
clean.
Inspect
these
areas of
heater
before each use. Have
heater Inspected yearly by a quali-
fied service person. Heater may
need more frequent cleaning due
to excessive lint from carpeting,
pet hair, bedding material, etc.
ODS/PILOT
AND BURNER
• Use a vacuum cleaner, pressurized air,
or small, soft bristled brush to clean.
CABINET
Air Passageways
• Use a vacuum cleaner or pressurized air
to clean.
Exterior
• Use a soft cloth dampened with a mild
soap and water mixture. Wipe the cabi-
net to remove dust.
Figure 27- Incorrect Pilot Flame Pattern
CORRECT
FLAME PATTERN
AT HIGH POSITION
Figure 28 - Correct Burner Flame Pattern
at High Position
INCORRECT
FLAME
PATTERN
AT HIGH POSITION
Yellow
Figure29-1ncorrectBurnerFlame Pattern
at High Position