WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result
causing property damage, personal injury, or loss
of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's in-
structions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a quali-
fied installer, service agency, or the gas supplier.
This appliance may be installed in an aftermarket*, permanently located, manufactured (mobile)
home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appli-
ance is not convertible for use with other gases.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
Save this manual for future reference.
Save this manual for future reference.
VENT-FREE HEATER
OWNER'S OPERATION AND
TM
INSTALLATION MANUAL
Shown with Optional
Mantel Which Features
a Built-in Base
WARNING: Improper installation,
adjustment, alteration, service, or
maintenance can cause injury or
property damage. Refer to this
manual for correct installation and
operational procedures. For as-
sistance or additional information
consult a qualified installer, ser-
vice agency, or the gas supplier.
WARNING: This is an unvented
gas-fired heater. It uses air (oxy-
gen) from the room in which it is
installed. Provisions for adequate
combustion must be provided.
Refer to Air For Combustion and
Ventilation section on page 5 of
this manual.

Advertisement

Table of Contents
loading

Summary of Contents for Desa VMH3000TPA

  • Page 1 For more information, visit www.desatech.com For more information, visit www.desatech.com RFN30TA RFP30TA VMH3000TNA VMH3000TPA 15,000 to 30,000 Btu/Hr with Thermostat WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS SAFETY INFORMATION TABLE OF CONTENTS SAFETY INFORMATION ... 2 LOCAL CODES ... 3 PRODUCT IDENTIFICATION ... 3 UNPACKING ... 3 PRODUCT FEATURES ... 4 ASSEMBLING HEATER ... 4 AIR FOR COMBUSTION AND VENTILATION ... 5 INSTALLATION ... 8 OPERATING HEATER ...
  • Page 3: Local Codes

    SAFETY INFORMATION Continued This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. Do not place propane/LP supply tank(s) inside any structure. Lo- cate propane/LP supply tank(s) outdoors (propane/LP units only). 3.
  • Page 4: Product Features

    PRODUCT FEATURES ASSEMBLING HEATER Removing Front Panel Of Heater Installing Hood Installing Log PRODUCT FEATURES SAFETY PILOT This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent- free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.
  • Page 5: Air For Combustion And Ventilation

    ASSEMBLY Continued ATTACHING BRASS FRONT TRIM TO FRONT PANEL Locate brass front trim in brass trim package. Slide the head of two truss-head screws from hardware packet into each end of brass front trim (see Figure 4). Line up screws with holes in front panel (see Figure 3, page 4).
  • Page 6: Providing Adequate Ventilation

    AIR FOR COMBUSTION AND VENTILATION Providing Adequate Ventilation Determining Fresh Air Flow For Heater Location AIR FOR COMBUSTION AND VENTILATION Continued PROVIDING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation. All spaces in homes fall into one of the three following ventilation classifications: Unusually Tight Construction...
  • Page 7: Ventilation Air

    AIR FOR COMBUSTION AND VENTILATION Continued The space in the above example is a confined space because the actual Btu/ Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows: A.
  • Page 8: Installation

    INSTALLATION Check Gas Type Installation Items Locating Heater INSTALLATION NOTICE: This heater is intended for use as supple- mental heat. Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater.
  • Page 9: Installation Options

    INSTALLATION Continued THERMOSTAT SENSING BULB The thermostat sensing bulb has been placed inside the heater for protection during shipping. Locating Thermostat Sensing Bulb Remove front panel of heater (see Figure 2, page 4). Locate thermostat sensing bulb just under burner assembly. IMPORTANT: Attach thermostat sensing bulb to back of heater for proper operation.
  • Page 10 INSTALLATION A. Mounting Heater To Wall (Cont.) B. Mounting Heater On Optional Hearth Base INSTALLATION Continued Attaching To Wall Anchor Method For attaching mounting bracket to hollow walls (wall areas between studs) or solid walls (concrete or masonry). Drill holes at marked locations using 5/16" drill bit. For solid walls (concrete or masonry), drill at least 1"...
  • Page 11 C. Mounting Heater With Optional Hearth Base (If Applicable) To Optional Mantel INSTALLATION Continued Note: It is an option to secure GHB802A model hearth base to floor. You must secure the GHB802B, GHB802C, or GHB38 series model hearth base to floor. To secure hearth base to floor, follow instructions under Securing Hearth Base to Floor, page 11.
  • Page 12: Connecting To Gas Supply

    INSTALLATION Connecting To Gas Supply INSTALLATION Continued CONNECTING TO GAS SUPPLY WARNING: This appliance requires a 3/8" NPT (National Pipe Thread) inlet connection to the pres- sure regulator. WARNING: A qualified service person must con- nect heater to gas supply. Follow all local codes. WARNING: Never connect natural gas heater to private (non-utility) gas wells.
  • Page 13: Checking Gas Connections

    INSTALLATION Continued CHECKING GAS CONNECTIONS WARNING: Test all gas piping and connections for leaks after installing or servicing. Correct all leaks at once. WARNING: Never use an open flame to check for a leak. Apply a noncorrosive leak detection fluid to all joints.
  • Page 14: Operating Heater

    OPERATING HEATER For Your Safety Read Before Lighting Lighting Instructions OPERATING HEATER FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing prop- erty damage, personal injury or loss of life. A.
  • Page 15: Inspecting Burner

    OPERATING HEATER Continued TO TURN OFF GAS TO APPLIANCE Shutting Off Heater Turn control knob clockwise Clockwise Turn off all electric power to the appliance if service is to be performed. Shutting Off Burner Only (pilot stays lit) Turn control knob clockwise Clockwise THERMOSTAT CONTROL OPERATION...
  • Page 16: Cleaning And Maintenance

    CLEANING AND MAINTENANCE Cleaning Burner Injector Holder And Pilot Air Inlet Hole Cabinet CLEANING AND MAINTENANCE WARNING: Turn off heater and let cool before cleaning. CAUTION: You must keep control areas, burner, and circulating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service person.
  • Page 17: Troubleshooting

    TROUBLESHOOTING Note: For additional help, visit DESA International’s technical service web site at www.desatech.com. Note: All troubleshooting items are listed in order of operation. OBSERVED PROBLEM When ignitor button is pressed, there is no spark at ODS/pilot When ignitor button is pressed, there is...
  • Page 18 TROUBLESHOOTING TROUBLESHOOTING Continued OBSERVED PROBLEM Burner does not light after ODS/pilot is lit Delayed ignition of burner Burner backfiring during combustion Yellow flame during burner combustion Slight smoke or odor during initial operation Heater produces a whistling noise when burner is lit White powder residue forming within burner box or on adjacent walls or furniture For more information, visit www.desatech.com...
  • Page 19 TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • Page 20: Specifications

    PARTS NOT UNDER WARRANTY Contact authorized dealers of this product. If they can’t supply original replacement part(s), either contact your nearest Parts Cen- tral (see page 24) or call DESA International at 1-866-672-6040 for referral information. When calling DESA International, have ready: •...
  • Page 21: Accessories

    Purchase these heater accessories from your local dealer. If they can not supply these accessories, either contact your nearest Parts Central (see page 24) or call DESA International at 1-866-672-6040 for information. You can also write to the address listed on the back page of this manual.
  • Page 22: Illustrated Parts Breakdown And Parts List

    ILLUSTRATED PARTS BREAKDOWN ILLUSTRATED PARTS BREAKDOWN RFN30TA RFP30TA VMH3000TNA VMH3000TPA For more information, visit www.desatech.com For more information, visit www.desatech.com 109889...
  • Page 23: Parts List

    100562-01 100563-01 101899-01 100769-02 100642-01 100565-01 For more information, visit www.desatech.com For more information, visit www.desatech.com 109889 PART NUMBER RFP30TA VMH3000TPA DESCRIPTION 098304-01 Screw, #10 x 3/8" 100566-01CK Front Panel 100573-01BR Screen Assembly 100568-02 Burner Shield 107122-01 Log, Service Kit 098303-02 Screw, #8 x 3/8"...
  • Page 24: Parts Centrals

    PARTS CENTRALS PARTS CENTRALS These Parts Centrals are privately-owned businesses. They have agreed to support our customer’s needs by providing original replacement parts and accessories. Baltimore Electric 1348 Dixwell Avenue Hamden, CT 06514-0322 1-800-397-7553 203-248-7553 Parts Department Portable Heater Parts 342 N.
  • Page 25: Owner's Registration Form

    Address: City: Home Phone: E-Mail: Please answer the following questions to register your product with DESA International: Where will the product be used? Living/Family Room Office/Warehouse If you bought this product yourself, did you plan to purchase this type of product before going into the store?
  • Page 26 Postage Required 2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 For more information, visit www.desatech.com For more information, visit www.desatech.com 109889...
  • Page 27 NOTES NOTES _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ For more information, visit www.desatech.com For more information, visit www.desatech.com 109889...
  • Page 28 Model Serial No. Date Purchased For more information, visit www.desatech.com For more information, visit www.desatech.com 2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desatech.com 109889 01 NOT A UPC 109889-01 Rev. A 02/02 109889...

This manual is also suitable for:

Rfn30taRfp30taVmh3000tna

Table of Contents