VENTILATION
AIR
Ventilation Air From Inside
Building
This fresh air would come from an adjoining
unconfined space. When ventilating to an
adjoining unconfined space, you must pro-
vide two permanent openings: one within
12" of the ceiling and one within 12" of the
floor on the wall connecting the two spaces
(see options 1and 2, Figure 8). You can also
remove door into adjoining room (see op-
tion 3, Figure 8). Follow the National Fuel
Gas Code NFPA 54/ANSI Z223.1, Section
5.3, Air for Combustion and Ventilation for
required size of ventilation grills or ducts.
_I'WARNING:
Rework
work-
sheet, adding the space of the
adjoining unconfined space. The
combined
spaces
must
have
enough fresh air to supply all
appliances In both spaces.
Ventilation
Air From Outdoors
Provide extra fresh air by using ventilation
grills or ducts. You must provide two per-
manent openings: one within 12" of the
ceiling and one within 12" of the floor.
Connect these items directly to the outdoors
or spaces open to the outdoors. These spaces
include attics and crawl spaces. Follow the
National Fuel Gas Code NFPA 54/ANSI
Z223.1, Section 5.3, Air for Combustion and
Ventilation for required size of ventilation
grills or ducts.
IMPORTANT: Do not provide openings for
inlet or outlet air into attic if attic has a
thermostat-controlled power vent. Heated air
entering the attic will activate the power vent.
Ventilation
Grills
Or
into Adjoining
Remove
Room,
Door into
Option 1
Adjoining
Room,
Option 3
©
1
S
Ventilation Grills
Into Adjoining Room,
Figure 8 - Ventilation Air from Inside Building
Outlet
Air
To Attic
Inlet
Air
To
Crawl
Space
Inlet Air
Ventilated
Crawl Space
Figure 9 - Ventilation Air from Outdoors