Pepperl+Fuchs KFU8-UFC-Ex1.D System Manual

Pepperl+Fuchs KFU8-UFC-Ex1.D System Manual

K-system isolated barriers

Advertisement

K-System
Isolated Barriers
System Manual
ISO9001

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KFU8-UFC-Ex1.D and is the answer not in the manual?

Questions and answers

Summarization of Contents

Introduction
Content of this Document
Details the information contained in this document for product lifecycle stages.
Target Group, Personnel
Defines responsibilities and qualifications for product handling and operation.
Symbols Used
Explains warning and informative symbols used throughout the document.
Product Specifications
Function
Describes the purpose and operation of isolated barriers in hazardous areas.
Housing Styles
Details the different housing widths (KC, KF, KH) and mounting options.
Terminals
Explains the features and types of removable terminal blocks used in devices.
Terminal Designation
Illustrates the terminal layout for KC and KF device housings.
Color Identification
Explains the meaning of device colors for power supply and signal type.
Status Indicators of the Isolators
Details the meaning of LED indicators (Green, Red, Yellow) for device status.
Operating Elements
Describes various operating elements like DIP switches, rotary switches, and potentiometers.
Label Carrier
Explains options for labeling devices with label carriers or adhesive labels.
DIN Mounting Rail
Describes the standard 35 mm DIN mounting rail for device installation.
Power Rail
Details the Power Rail system for power distribution and bus signals.
Mounting and Installation
Mounting
Covers safety precautions and methods for mounting devices onto mounting rails.
Connection
Provides instructions and safety warnings for connecting devices and circuits.
Field Side Connection
Details connecting field devices, including safety regarding separation distances.
Control Side Connection
Explains how to connect devices and systems on the control side.
Power Supply Connection
Covers various options for connecting power supplies to the devices.
Establishing the Communication via Software
Guides on setting up communication with devices using software and adapters.
Configuration
Configuring the Device
Instructions on setting device parameters using operating elements and data sheets.
Operation
Fault Monitoring
Explains how faults like line issues and device faults are detected and reported.
Fault Output
Details how fault information is transmitted via LEDs, fault outputs, and collective error messages.
Current and Voltage Standard Signals
Describes standard analog signals (0/4-20mA, 0/2-10V, 0/1-5V) and NAMUR NE43.
Dismounting, Maintenance, and Repair
Disconnecting Circuits
Provides steps for safely disconnecting power, field, and control circuits.
Dismounting the Isolated Barrier
Step-by-step guide on how to remove an isolated barrier from a DIN mounting rail.
Technical Specifications
Technical Data
Lists electrical data for non-hazardous and hazardous areas, and characteristic safety values.
Model Number Description
Explains the coding system for model numbers, detailing each position's meaning.
Dimensions
Provides detailed dimensions for K-System Isolated Barrier housing types.

Table of Contents