Porsche 911 TURBO - 1989 Workshop Manual page 111

Hide thumbs Also See for 911 TURBO - 1989:
Table of Contents

Advertisement

Fuel Mixture
CHECKING
FUEL
DELIVERY
RATE
FOR CONTROL
PRESSURE
CIRCUIT
Requirements
Fuel pumps in correct opera-
tional condition.
Checking
1. Connect and bleed pressure gauge.
4. Turn on ignition.
2. Set switching valve to position 3.
5. Move switching valve to position 2 and let
electric fuel pumps run exactly 1 minute by
pulling off two-pin plug on mixture control unit.
Stop by switching valve to position 3 and meas.
ure delivery rate.
Test value: 160 to 240 cc/minute.
3. Unscrew hose from Special Tool P 378 on
warm-up regulator and hold end in a measur-
ing glass with volume of at least 500 cc.
If measured value is outside of tolerances, the
cause will be in the fuel distributor. Replace fuel
distributor.