Blower modules
The BladeCenter unit comes with two hot-swap blower modules for cooling
redundancy. The blower speeds vary depending on the ambient air temperature at
the front of the BladeCenter unit and the temperature of internal BladeCenter
components. If the ambient temperature is 22°C (72°F) or below, the BladeCenter
unit blowers will run at 30% of their maximum rotational speed, increasing their
speed as required to control internal BladeCenter temperature. If the ambient
temperature is above 22°C (72°F), the blowers will run at 80% of their maximum
rotational speed, increasing their speed as required to control the internal
BladeCenter unit temperature. If a blower fails, the remaining blower continues to
cool the BladeCenter unit and blade servers. Replace a failed blower as soon as
possible, to restore cooling redundancy. See the Hardware Maintenance Manual
and Troubleshooting Guide for instructions.
The IBM Documentation CD
You can run the IBM Documentation CD on any personal computer that meets the
hardware and software requirements.
The IBM Documentation CD contains documentation for your blade server in
Portable Document Format (PDF) and includes the IBM Documentation Browser to
help you find information quickly.
Hardware and software requirements
The IBM Documentation CD requires the following minimum hardware and
software:
v Microsoft Windows NT, Windows 2000, or Red Hat Linux
v 100 MHz microprocessor.
v 32 MB of RAM.
v Adobe Acrobat Reader 3.0 (or later) or xpdf, which comes with Linux operating
Using the Documentation Browser
Use the Documentation Browser to browse the contents of the CD, read brief
descriptions of the documents, and view documents using Adobe Acrobat Reader or
xpdf. The Documentation Browser automatically detects the regional settings in use
in your system and displays the documents in the language for that region (if
available). If a document is not available in the language for that region, the
English-language version is displayed.
Use one of the following procedures to start the Documentation Browser:
v If Autostart is enabled, insert the CD into the CD drive. The Documentation
v If Autostart is disabled or is not enabled for all users, use one of the following
8
BladeCenter E Type 8677: Installation and User's Guide
systems.
Browser starts automatically.
procedures:
– If you are using a Windows operating system, insert the CD into the CD drive
and click Start --> Run. In the Open field, type
e:\win32.bat