Download Print this page

ZURN AquaSense Z6913-XL-HYD Installation, Operation, Maintenance And Parts Manual

Sensor-operated lavatory faucets

Advertisement

Quick Links

Z6913-XL
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
ADVERTENCIA: Cáncer y daño reproductivo - www.P65Warnings.ca.gov
AVERTISSEMENT: Cancer et effets néfastes sur la reproduction - www.P65Warnings.ca.gov
All goods sold hereunder are warranted to be free from defects in material and factory workmanship for a period of three years from the
date of purchase. Decorative finishes warranted for one year. We will replace at no costs goods that prove defective provided we are
notified in writing of such defect and the goods are returned to us prepaid at Sanford, NC, with evidence that they have been properly
maintained and used in accordance with instructions. We shall not be responsible for any labor charges or any loss, injury or damages
whatsoever, including incidental or consequential damages. The sole and exclusive remedy shall be limited to the replacement of the
defective goods. Before installation and use, the purchaser shall determine the suitability of the product for his intended use and the
purchaser assumes all risk and liability whatever in connection therewith. Where permitted by law, the implied warranty of merchantabil-
ity is expressly excluded. If the products sold hereunder are "consumer products," the implied warranty of merchantability is limited to a
period of three years and shall be limited solely to the replacement of the defective goods. All weights stated in our catalogs and lists are
approximate and are not guaranteed.
NOTICE: READ ENTIRE MANUAL PRIOR TO INSTALLING PRODUCT.
Rev. D | Date: 01/03/23 | C.N. No. 144945 | Prod./Dwg. No. FV806
Patent zurn.com/patents
US 1.855.ONE.ZURN CANADA 1.877.892.5216
ZURN.COM
AquaSense
Z6913-XL and Z6915-XL Series
Sensor-Operated Lavatory Faucets for Battery,
Plug-In, or Hardwire Installations, Connected
Installation, Operation, Maintenance,
and Parts Manual
LIMITED WARRANTY
®
Z6915-XL

Advertisement

loading
Need help?

Need help?

Do you have a question about the AquaSense Z6913-XL-HYD and is the answer not in the manual?

Questions and answers

Summary of Contents for ZURN AquaSense Z6913-XL-HYD

  • Page 1 All weights stated in our catalogs and lists are approximate and are not guaranteed. NOTICE: READ ENTIRE MANUAL PRIOR TO INSTALLING PRODUCT. Rev. D | Date: 01/03/23 | C.N. No. 144945 | Prod./Dwg. No. FV806 Patent zurn.com/patents US 1.855.ONE.ZURN CANADA 1.877.892.5216 ZURN.COM...
  • Page 2 This Page Intentionally Left Blank...
  • Page 3 Aqua Sense Faucets Package Contents ® Z6915-XL-W1 (As Shown) Z6913-XL-W1 (As Shown) Spout Assembly Spout Assembly (Studs not Shown) Aerator Aerator and Key and Key Base Gasket Base Gasket Shank Mounting Kit Shank Mounting Kit Electronics Box with Ceramic Electronics Box Valve with Ceramic Filter...
  • Page 4: Required Tools

    Z6915-XL-W2 (As Shown) Z6913-XL-W2 (As Shown) Aerator Spout Assembly and Key (Studs not Shown) Aerator and Key Spout Assembly Base Gasket Base Gasket Batteries Batteries Shank Shank Mounting Kit Mounting Kit Sensor Inline Sensor Inline Connector Connector Hydrogenerator Hydrogenerator Electronics Box Electronics Box with Solenoid with Solenoid...
  • Page 5 (2) this device must accept any interference received, including interference that may cause undesired operation. The following information refers to Zurn Smart Connected Products, types: -W1 and -W2. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference intended for use in non-residential/non-domestic environments.
  • Page 6 • Installer is responsible for ensuring the product is installed and conforms to all plumbing codes and ordinances. • Do not convert or modify this Zurn product yourself. All warranties will be voided. • Water supply lines must be sized according to building designer in order to provide adequate water supply for each fixture.
  • Page 7 Cover Plate Installation Instructions (All Configurations) 1. (For faucets with -CP4 or -CP8 suffix). Pass sensor connector wire and shank through gasket. Align gasket with faucet bottom and press firmly together. Pass sensor connector and shank through cover plate and fasten to the faucet with the provided screws.
  • Page 8 Endpoint & Electronic Module Installation Instructions (-ACA/-CWB) 2. Tighten electronics module assembly to shank and connect Remove the electronics module from box water line(s). Connect Sensor. 3b. Optional HW6 (Hardwired 6V) version: Connect supplied inline 3a. Optional ACA version: Connect supplied inline connector and connector and hardwire adapter.
  • Page 9 Optional MJ unit (sold separately) Note: Do not connect more than 3 boxes to a single transformer -HW6 F F A A U U C C E E T T F F A A U U C C E E T T B B L L A A C C K K /W /WH H IT ITE E S S T T R R I I P P E E...
  • Page 10 Electronics Module Installation Instructions (-HYD) Connect hydrogenerator(A) downstream of electronics 2. Connect sensor inline connector to electronics module and module(B) and filter(C) to bottom of electronics module. hydrogenerator. 3. Open battery module using supplied Allen wrench and install 4. Tighten electronics module assembly with hydrogenerator to supplied alkaline batteries in the electronics module.
  • Page 11 Endpoint & Electronic Module Installation Instructions (-W1) 2. Connect endpoint and DC power cable. 1.a. Install endpoint on wall surface within 2 feet radius of faucet with dry wall anchors & screws or doubled sided VHB tape 1.b. For concealed wiring installation, drill 3/16” hole in wall surface for DC power cable , route wire-end through hole to HW6 unit.
  • Page 12 5.c. Optional MJ unit (sold separately) Note: Do not connect more than 3 boxes to a single transformer -HW6 F F A A U U C C E E T T F F A A U U C C E E T T B B L L A A C C K K /W /WH H IT ITE E S S T T R R I I P P E E...
  • Page 13 Monitor & Electronic Module Installation Instructions (-W2) Connect hydrogenerator(A) downstream of electronics Connect sensor inline connector to electronics module and to module(B); connect the electronics module(B) downstream of the hydrogenerator. filter(C). Do not connect the electronic module to spout. Loosen lid screw with supplied 3mm Allen wrench. Open lid and install supplied lithium batteries.
  • Page 14 Tighten electronics module assembly with the hydrogenerator 8. Ensure that sink is clear of tools/debris and is in normal to shank and connect water line(s). operating condition. Remove protective film from sensor lens if one is present. 9. Turn on water supply(ies). 10.
  • Page 15 Install Zurn Gateway per the Gateway Instructions Manual Request plumbSMART Administrator Account at 844-987-6737 Zurn creates your Enterprise Account for you! (You will be required to identify your building location, number of floors, and number of rooms.) Log in to plumbsmart.zurn.com Register each Connected Product in plumbSMART (Watch How-To Videos to Get Started.
  • Page 16 Adjustable modes and features selection (-W2/-HYD) To adjust features from default configuration, you must remove the battery tray. Once battery tray is removed you will see the switches. Switch Position: Purge (Hours) Disable: Time (Seconds) Less Time-out Mode Select Sensing Mode: Metering Mode: All switches shown in default mode.
  • Page 17 Check to en- sembles to the faucet shank. sure the gasket is installed and not damaged. If not installed, install gasket. If gasket is dam- aged, replace with new For further assistance with troubleshooting visit http://www.zurn.com FV806 Rev.D 01/03/23 Page 17...
  • Page 18 If not installed, install to the faucet shank. gasket. If gasket is damaged, replace with new For further assistance with troubleshooting visit http://www.zurn.com FV806 Rev. D 01/03/23 Page 18...
  • Page 19 Details tab is listed as “Activated” NETWORK: Senet SUBSCRIPTION STATUS: Activated LAST HEARD FROM: 07/14/2020, 04:29 PM CDT If listed as “Deactivated”, contact Zurn Customer Service at 1.855.ONE.ZURN (1.855.663.9876) for assistance. “Status – Good” posted in plumbSMART and faucet not Step 1 actuating Verify LoRa Monitor’s cables are connected to IR sensor...
  • Page 20 If LORA LED does not turn ON solid and ethernet cable connected, contact facility IT administrator to modify port rules to allow Zurn gateway to access the internet via local router. If gateway model is ETH/LTE, visually verify SIM card is installed in designated slot on the side of gateway.
  • Page 21 Filter and Mixing Valve Installation (All Configurations) Control Box Attach adapter or Braided Hose (-SSH) here with -MV and TMV-1 options P6900-120BC, Filter in standard faucet installation P6900-12BC Filter P6900-12BC Filter P6900-MV-ADAP [Supplied Adapter] for -MV & -TMV-1 Options -SSH Option Need to hold at pointed area by suitable To Control Box wrench or by hand while applying torque...
  • Page 22 Accessing the Solenoid (-W2/-HYD) To service solenoid use Phillips head screw driver to remove the With screws removed, the electronics box can slide off and allow screws on both sides of the electronics box. access to the solenoid for service. FV806 Rev.
  • Page 23 Z6913-XL-ACA/CWB & Z6915-XL-ACA/CWB Parts List Description Product No. Description Product No. Item 1A: Z6915 Spout Assembly with Item 6: -CWB Pigtail P6900-CWB P6915-XL-2 Sensor Item 7: Filter Kit P6900-120BC Item 1B: Z6913 Spout Assembly with Item 8: Filter Screen P6900-MV-7 P6913-XL-2 Sensor Item 9: Mixing Valve with Filter...
  • Page 24 Z6913-XL-HYD & Z6915-XL-HYD Parts List Description Product No. Description Product No. Item 1A: Z6915 Spout Assembly with Item 5: Electronics Box with Solenoid P6950-XL-B-L-V2 P6915-XL-2 Sensor Item 6: 4” Cast Cover Plate w/Gasket P6900-CP4 Item 1B: Z6913 Spout Assembly with Item 7: 8”...
  • Page 25 Z6913-XL-W1 & Z6915-XL-W1 Parts List Description Product No. Description Product No. Item 1A: Z6915 Spout Assembly with Sensor P6915-XL-2 Item 9: Filter Kit P6900-120BC Item 1B: Z6913 Spout Assembly with Sensor P6913-XL-2 Item 10: Filter Screen P6900-MV-7 Item 2A: Z6915 Base Plate Gasket P6915-42-WEDGE Item 11: Mixing Valve with Filter P6900-MV-XL...
  • Page 26 Z6913-XL-W2 & Z6915-XL-W2 Parts List Description Product No. Description Product No. Item 1A: Z6915 Spout Assembly with Sensor P6915-XL-2 Item 9: Filter Kit P6900-120BC Item 1B: Z6913 Spout Assembly with Sensor P6913-XL-2 Item 10: Filter Screen P6900-MV-7 Item 2A: Z6915 Base Plate Gasket P6915-42-WEDGE Item 11: Mixing Valve with Filter P6900-MV-XL...
  • Page 27 This Page Intentionally Left Blank...
  • Page 28 Rev. D | Date: 01/03/23 | C.N. No. 144945 | Prod./Dwg. No. FV806 Patent zurn.com/patents US 1.855.ONE.ZURN CANADA 1.877.892.5216 ZURN.COM...