Advertisement

Quick Links

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TM FAST and is the answer not in the manual?

Questions and answers

Summarization of Contents

Preface
Purpose of the documentation
Explains the manual's scope, covering module-specific info, general system info, and programming manual links.
Conventions
Advises users to observe notes marked with specific symbols for important information.
Siemens Industry Online Support
Guides users to find product support, application examples, services, and forums online.
Industry Mall
Provides information on Siemens' catalog and order system for automation and drive solutions.
Security information
Details industrial security functions, cyber threat prevention, and recommended practices for secure operation.
Open Source Software
Informs about the use of open-source software in the product firmware and Siemens' liability.
Documentation guide
Manual Collection S7-1500/ET 200MP
Describes the comprehensive collection of documentation for S7-1500 and ET 200MP systems available online.
SIMATIC S7-1500 comparison list for programming languages
Provides an overview of instructions and functions available for different controller families.
mySupport
Introduces a personal workspace for saving, requesting data, and managing support queries.
Application examples
Highlights resources offering tools and examples for solving automation tasks with multiple components.
Product overview
2.1 Properties
Details the technology module's features, including digital I/O, RS485/TTL channels, and configurable parameters.
Connecting
3.1 Pin assignment
Details the pin assignments for the technology module's front connector and infeed element.
Circuit diagram
Illustrates the electrical connections and internal circuitry of the technology module for digital I/O.
Digital inputs and outputs
Explains the configuration and characteristics of digital inputs, DIQm, and digital outputs.
Input delay and output settings
Covers input delay configurations and digital output parameters for signal quality and interference suppression.
Configuring/address space
4.1 Configuring
Outlines system environments and configuration software for using the TM FAST module with S7-1500/1200 and third-party systems.
4.2 Parameters of the configuration software
Describes configurable parameters for diagnostics, application startup, and reaction to CPU STOP.
4.3 Operation of the commissioning editor
Explains how to use the commissioning editor to control the module and read status information.
4.4 Address space
Specifies the input and output address space allocated to the TM FAST technology module.
4.5 Reaction to CPU STOP
Defines how the technology module responds when the CPU enters a STOP state.
4.6 Isochronous mode
Details the support for isochronous mode, synchronizing user program cycles and data transmission.
Programming
5.1 Programming with STEP 7 (TIA Portal)
Introduces the LTMFAST instruction library for controlling the TM FAST module within STEP 7 (TIA Portal).
5.2 Handling the TM FAST application
Describes how to define module functionality by programming TM FAST applications for the FPGA.
Interrupts/diagnostic alarms
6.1 Status and error displays
Explains the meaning of the RUN, ERROR, MAINT, PWR, and channel LEDs on the TM FAST module.
6.2 Diagnostic alarms
Details how to enable diagnostic interrupts and lists possible diagnostic alarms and their remedies.
Technical specifications
Digital inputs
Specifies the number, parameterization, and voltage characteristics of the module's digital inputs.
Digital outputs
Details the number, current sinking/sourcing, and switching capacity of the module's digital outputs.
Diagnoses
Lists the types of diagnoses the module supports, including supply voltage monitoring and wire-break detection.
Dimensions and weights
Provides the physical dimensions (width, height, depth) and approximate weight of the technology module.
Parameter data record
B.1 Parameter assignment and structure of the parameter data record
Explains how to change module parameters via the user program using data record 128.
B.2 Parameter validation error with data record 128
Describes how the module validates parameters and lists error codes for invalid or inconsistent data.
Data record TMFASTControlREC
C.1 Use and structure of TMFASTControlREC (data record 100)
Details the structure of data record 100 used for managing the TM FAST application and reading status.
C.2 Validation error with data record 100
Lists module-specific error codes and remedies for validation errors related to data record 100.
Data record TMFASTUserWriteREC
D.1 Use and structure of TMFASTUserWriteREC (data record 101)
Explains data record 101 for transferring user-defined acyclic data to and from the module.
D.2 Validation error with data record 101
Lists module-specific error codes and remedies for validation errors related to data record 101.
Data record TMFASTUserReadREC
E.1 Use and structure of TMFASTUserReadREC (data record 102)
Details data record 102 for reading user-defined acyclic data from the module.
E.2 Possible errors with data record 102
Lists module-specific error codes and remedies for errors encountered when reading data record 102.

Table of Contents