INSTALLATION
Continued
Carefully follow the instructions below. This will
ensure safe installation.
Minimum Clearances For Side
Combustible Material, Side Wall, and
Ceiling
A. Clearances from the side of the fireplace
cabinet to any combustible material and wall
should follow diagram in Figure 5.
Example: The face of a mantel, bookshelf,
etc. is made of combustible material and
protrudes 3
/
" from the wall. This combus-
1
2
tible material must be 4" from the side of the
fireplace cabinet (see Figure 5).
B. Clearances from the top of the fireplace
opening to the ceiling should not be less
than 42 inches.
Example
*Minimum 16 inches from Side Wall
Figure 5 - Minimum Clearance for
Combustible to Wall
INSTALLATION SEQUENCE
After unpacking fireplace (see Unpacking, page 5),
we suggest that you install your fireplace system
in the following sequence:
1. Removal of fireplace floor assembly (re-
quired)
2. Electrical connections for power cord (required)
3. Relocating wall switch (optional)
4. Installing blower accessory (optional)
5. Connecting fireplace to gas supply (required)
6. Checking gas connections (required)
7. Firebox installation, conventional or built-in
(required)
8. Installing perimeter trim (optional)
9. Installing fireplace hood (required)
10. Installing logs (required)
11. Installing fireplace screen (required)
Use the following instructions to complete each
step.
113134-01B
*
Screw
Fireplace
Floor
Assembly
Figure 6 - Removing Fireplace Floor
www.desatech.com
Assembly
9