C2648
Remote Condenser Models - User Manual

Product Description and Electrical Requirements

Ice Machine
Model
Dimensions
w" x d" x h"
48 x 28 x 31
C2648SR-3
same
C2848MR-3
Remote Condenser Footprint: On center mounting hole spread: 27.57" w x 33.38" d. See page 5.
Minimum bin top opening: 20.5" x 40.5" includes drop zones and ultrasonic sensor location. See page 5.
*Or HACR circuit breakers.
Table notes: Series revision code omitted. All the
listed condensers include a headmaster valve.
Ratings include the remote condenser motor, as it
is designed to be powered by the ice machine. If
connecting remote condenser independently of the
ice machine, use the information on the
condenser's dataplate for fuse and wire sizes.
Condensers are UL listed for these model ice
machines.
Central Condenser (Rack) Coils
The ice machine may be connected to a central
condenser coil. The requirements are:
Coil – not previously used with mineral oil
system. Virgin coil preferred.
Correct size (internal volume) and capacity
(BTUH). Contact Scotsman for data.
Includes a headmaster valve for discharge
pressure control rated at 217 PSIG.
Fan motor on all the time or controlled to be
on whenever the ice machine is operating.
U.L. listed for the ice machine
Non-Scotsman condensers must have prior
Scotsman Engineering approval for warranty
coverage to be in effect.
Use
Electrical
condenser
208-230/60/3
PRC241-32A
208-230/60/3
PRC241-32A
Precharged tubing kits:
The ice making head's and the remote condenser's
refrigeration circuits must be connected. They are
designed to be connected using precharged
refrigerant tubing, supplied in kits of liquid and
discharge tubes. Several lengths are available,
order the one that just exceeds the length needed
for the site.
C2648
No additional refrigerant is required.
October 2010
Page 4
Minimum
Maximum
Circuit
Fuse* Size
Ampacity
21.6
30
21.6
30
10'
20'
40'
RTEL10
RTEL25
RTEL40
Suggested
Fuse* Size
30
30
75'
RTEL75

Advertisement