systems that only support active-passive connections, such as IBM's DS3000, DS4000, and
DS5000 subsystems, failover is the only method allowed.
The access method can be configured on a per-LUN basis from the VIOS command line via a
Telnet or SSH session. To show the current multi-path algorithm:
•
lsdev –dev hdiskX –attr algorithm
To change the multi-path algorithm:
•
chdev –dev hdiskX –attr algorithm=round_robin, or
•
chdev –dev hdiskX –attr algorithm=fail_over
These commands must be repeated for each hdisk.
9.3.2.2. Redundant VIOS LPARs with client-side MPIO
Beginning with IBM i 6.1 with Licensed Internal Code (LIC) 6.1.1, the IBM i Virtual SCSI (VSCSI)
client driver supports MPIO through two or more VIOS partitions to a single set of LUNs (up to a
maximum of 8 VIOS partitions). This multi-path configuration allows a VIOS partition to fail or be
brought down for service without IBM i losing access to the disk volumes since the other VIOS
partition(s) remain active. The following diagram illustrates the new capability for IBM i:
25