Dell PowerVault MD1120 Hardware Owner's Manual page 44

Hardware owner's manual (pdf)
Hide thumbs Also See for PowerVault MD1120:
Table of Contents

Advertisement

Disconnecting the cables to the enclosure or EMM while the server is
online
Powering down the enclosure while the server is online
NOTE:
In a split-mode configuration, these conditions apply to the server that is
directly attached to the affected EMM. In a unified-mode configuration, these
conditions apply when communication is lost to any enclosure in the daisy chain.
Problem
The PERC 6/E Adapter Ctrl-R utility reports:
Physical disks and virtual disks as Offline, Degraded, Failed, or Foreign
Server Administrator Storage Management reports:
Lost Communication alert(s) to the Server Administrator Alert Log
The enclosure, physical disks, and virtual disks as Offline, Degraded,
Failed, or Foreign
NOTE:
These messages are logged as a result of a loss of communication and do
not indicate actual hardware component failures.
Action
1 Power down the server.
2 Verify that all storage subsystem cabling between the PERC 6/E Adapter
and all attached enclosures, including daisy-chained enclosures, is properly
connected and secured.
3 Ensure that all the enclosures are powered up.
4 Power up the server.
The PERC 6/E Adapter should recover without any additional user
intervention or warning/error messages.
Problem
Warning Messages During POST:
Foreign Configuration
Failed Virtual Disks
44
Troubleshooting Your Enclosure

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powervault md1120 amt

Table of Contents