Optional Wall Switch - Desa Vanguard VMH26PR Owner's Operation And Installation Manual

Vent-free propane/lp gas compact classic hearth® fireplace
Table of Contents

Advertisement

INSTALLATION
Continued
6. Connect one bare wire end to each ter-
minal ("W" and "R") of the thermostat
base (see Figure 34).
7. Install the base onto the wall with the
provided screws.
8. Move the temperature adjustment back
and forth to insure the bimetal is free
from restrictions.
9. Replace the cover onto the base. (Upon
installation, the thermostat must be al-
lowed to stabilize at room temperature
for a minimum of 30 minutes for proper
operation).
10. Set switch on heater to Auto position.
11. Set the temperature adjustment to the
desired setting. This thermostat has
been electronically calibrated at the
factory. No adjustment or leveling is
necessary.
Switch on Gas
Heater
One
terminal of
25 ft. wire
Figure 32 - Connecting Wire Terminals
Feed wires through
rectangular slots
Figure 33 - Back View of Thermostat Base
104323
Terminal "W"
Terminal "R"
Figure 34 - Thermostat Base Terminals
"W" and "R"
Control
Valve
To Wall
Thermostat
or Switch
OWNER'S MANUAL

OPTIONAL WALL SWITCH -

GWMS2
W
R
1.
2.
3.
IMPORTANT: The wire may be shortened
but must not be lengthened.
To Wall
4.
Thermostat or
Switch
5.
17
WARNING: Read and follow
installation instructions. Instal-
lation should be done by a quali-
fied installer familiar with low-
voltage wiring procedures.
WARNING: Do not connect
this switch to any electrical
source! Electrical shock and/or
fire hazard will occur.
Connect one terminal of 25 ft. wire to
bottom contact of switch (see Figure 32).
Connect remaining wire terminal to the
"TH" terminal on the control valve.
Make sure that wire terminals are in
the positions on your unit as pictured
in Figure 32. If wires are not "crossed"
the thermostat will not work.
Route the 25 ft. wire to a convenient
location to mount your wall switch (no
outside walls).
WARNING: Do not connect
the switch to a power source.
Electrical shock and/or fire haz-
ard will occur.
Connect one bare wire end to each of
the terminals of the provided wall switch.
Install the wall switch and cover in the
wall.

Advertisement

Table of Contents
loading

Table of Contents

Save PDF