Redundancy And Error Handling - Intel RS2BL040 - Raid Controller Hardware User's Manual

Hardware user guide
Hide thumbs Also See for RS2BL040 - Raid Controller:
Table of Contents

Advertisement

Redundancy and Error Handling

In-band and out-of-band SES2.
Enclosure management support.
Support the internal SAS Sideband signal SFF-8485 (SGPIO) interface.
Drive coercion (auto-resizing to match existing disks).
Auto-detection of failed drives with transparent rebuild. There must be disk activity
(I/O to the drive) for a missing drive to be marked as failed.
Auto-resume on reboot of initialization or rebuild (must be enabled before virtual
disk creation).
Smart initialization automatically checks consistency of virtual disks if there are five
or more disks in a RAID 5 array, which optimizes performance by enabling read-
modify-write mode. RAID 5 arrays of only three or four drives use Peer Read mode.
Dirty cache LED plus error reporting for cache write to disk.
Smart Technology predicts failures of drives and electronic components.
Patrol Read checks drives and maps bad sectors.
Commands are retried at least four times.
Firmware provides best effort to recognize an error and recover if possible.
Failures are logged from controller and drive firmware, and SMART monitor.
Failures are logged in NVRAM, viewable from OS Event Log, Intel
Console 2; CIM, LEDs, and via alarm.
Multiple cache options allow configuration-specific performance optimization:
— Write-back: Faster because it does not wait for the disk but data will be lost if
— Write-through: Usually slower but ensures data is on the disk.
— Read Ahead: Predicts next read will be sequential and buffers this data into the
— Non-Read Ahead: Always reads from the drive after determining exact location
— Adaptive Read Ahead: Reads ahead and caches data only if doing sequential
— I/O setting: Determines whether read operations check the cache before reading
Redundancy through:
— Configuration stored in non-volatile RAM and on the drives (COD).
— Hot-swap support.
4
power is lost.
cache.
of each read.
reads.
from disks.
✧ Cache I/O: Checks cache first; only reads disk if data is not in the cache.
✧ Direct I/O: Reads data directly from disk (not cache).
Intel® RAID Controller RS2BL040 Hardware User's Guide
®
RAID Web

Advertisement

Table of Contents
loading

Table of Contents