Electrical Characteristics
Characteristic
PCI +12 V
PCI +3.3 Aux
Temperature
Non-operating
Operating
PCI +3.3 V
Relative Humidity
Operating
Airflow
Safety Characteristics
The Intel
flammability rating 94 V0. Each bare board is marked with the supplier name or
trademark, type, and UL flammability rating. For the boards installed in a PCI bus slot, all
voltages are lower than the SELV 42.4 V limit.
Intel® RAID Controller RS2BL040 Hardware User's Guide
Table 5. Electrical Characteristics
1.0A
30 mA
-30°C to +80°C without the optional battery /
0°C to 45°C with the optional battery
0°C to 60°C without the optional battery /
0°C to 45°C with the optional battery
773 mA
5%-90% non-condensing ( 20%-80% non-condensing for the RAID
controllers)
> 200 linear feet per minute (LFPM)
®
RAID Controller RS2BL040 meets or exceeds the requirements of UL
Values