Manual Lighting Procedure; To Turn Off Gas To Appliance - Comfort Glow CSDBN Owner's Operation And Installation Manual

Cast iron stove and direct-vent (freestanding fireplace heater) burner system
Table of Contents

Advertisement

OPERATING STOVE AND BURNER SYSTEM
26
Lighting Instructions (Cont.)

To Turn Off Gas To Appliance

Manual Lighting Procedure

Optional Hand-Held Remote Operation
OPERATING STOVE WITH
BURNER SYSTEM
Continued
9. Push in gas control knob all the way and hold. Immedi-
ately light the pilot by repeatedly depressing the piezo spark
ignitor until a flame appears. Continue to hold for about
one (1) minute after the pilot is lit. Release gas control knob
and it will pop back. Pilot should remain lit. If it goes out,
repeat steps 5 through 8, page 25.
• If gas control knob does not pop up when released, stop
and immediately call your service technician or gas
supplier.
• If the pilot will not stay lit after several tries, turn the gas
control knob to "OFF" and call your service technician
or gas supplier.
10. Turn gas control knob counterclockwise
11. Turn on all electric power to the burner system.
12. Turn the ON/OFF switch to ON position.
13. This valve is equipped with a HI/LO feature. Set burner
system input as desired.
14. Close lower panel.
TO TURN OFF GAS
TO APPLIANCE
1.
Turn ON/OFF switch, located on side of rear cover, to "OFF".
2a. Open lower door panel.
2b.
If Using Optional Hand-Held Remote:
located on side of rear cover, in the OFF position to pre-
vent draining battery.
3. Turn off all electrical power to the appliance if service is to
be performed.
4. Push in gas control knob slightly and turn clockwise
to "OFF".
5. Close lower panel.
Shutting Off Burners Only (pilot stays lit)
You may shut off the burners and keep the pilot lit by doing one
of the following:
1. Turn gas control knob clockwise
position.
2.
Set selector switch in the OFF position.
Gas Control Knob
Piezo
Ignitor
Figure 60 - Control Valve
For more information, visit www.desatech.com
For more information, visit www.desatech.com
to "ON".
Set selector switch,
to the PILOT
Variable
Control Knob
LO
IN
OUT
MANUAL LIGHTING
PROCEDURE
1. Remove glass door (see Removing/Replacing Glass Door,
page 6).
2. Follow steps 1 through 8 under Lighting Instructions, page 25.
3. Depress gas control knob and light pilot with match.
4. Keep gas control knob pressed in for 30 seconds after lighting
pilot. After 30 seconds, release gas control knob. Now follow
steps 10 through 14 under Lighting Instructions, column 1.
5. Replace glass door (see Removing/Replacing Glass Door,
page 6).
OPTIONAL HAND-HELD
REMOTE OPERATION
Note: All remote control accessories must be purchased sepa-
rately (see Accessories, page 38). Follow instructions included
with the remote control.
NOTICE: You must light the pilot before using the
hand-held remote control unit. See Lighting Instruc-
tions on page 25.
1. After lighting, let pilot flame burn for about one minute.
Turn control knob to ON position. Adjust flame adjustment
knob anywhere between HI and LO. Slide the selector switch
to the REMOTE position (see Figure 61). Note: The burner
may light if hand-held remote was on when selector switch
was last turned off. You can now turn the burner on and off
with the hand-held remote control unit.
IMPORTANT: Do not leave the selector switch in the RE-
MOTE or ON position when the pilot is not lit. This will
drain the battery.
Selector Switch in Remote
Position (Optional Remote
Control)
Figure 61 - Setting the Selector Switch, Gas Control Knob, and
Variable Control Knob for Remote Operation
Gas Control Knob
Variable
in On Position
Control Knob
LO
IN
OUT
111739-01A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Csdpbn

Table of Contents