SOLIS S5-EH1P4.6K-L Instruction Manual

SOLIS S5-EH1P4.6K-L Instruction Manual

Hide thumbs Also See for S5-EH1P4.6K-L:

Advertisement

Ginlong Technologies Co., Ltd.
No. 57 Jintong Road, Binhai Industrial Park, Xiangshan, Ningbo,
Zhejiang, 315712, P.R.China.
Tel: +86 (0)574 6578 1806
Fax: +86 (0)574 6578 1606
Please adhere to the actual products in case of any discrepancies in this user manual.
If you encounter any problem on the inverter, please find out the inverter S/N
and contact us, we will try to respond to your question ASAP.
Solis S5-EH1P-L Hybrid Inverter
Instruction Manual
Ginlong Technologies Co., Ltd.
(ForAustralia)
Ver1.0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S5-EH1P4.6K-L and is the answer not in the manual?

Questions and answers

Summarization of Contents

Introduction
1.1 Product Description
Details the Solis S5-EH1P-L Series residential hybrid inverter capabilities and models.
1.2 Packaging
Lists all items included in the inverter packaging for user verification.
Safety & Warning
2.1 Safety & General Instructions
Defines safety terms (Danger, Warning, Caution, Note) and general safety guidelines for inverter use.
2.3 Notice For Use
Specifies conditions and requirements for proper inverter installation and use.
Overview
3.1 Screen, Keypad & Terminals
Describes the inverter's screen interface, keypad functions, and terminal connections.
Installation
4.1 Select a Location for the Inverter
Provides criteria for choosing a suitable installation location for the inverter.
4.2 Mounting the Inverter
Details the steps and requirements for physically mounting the inverter.
4.3 PV and Battery Input Connections
Explains how to correctly connect the PV input and battery to the inverter.
4.5 AC Output Connection
Provides instructions for assembling and connecting the AC output.
4.6 Meter Installation
Describes the installation process for various meter types compatible with the inverter.
4.7 Communication and Ground Connections
Details the assembly of communication cables and external ground connection.
4.9 DRED, RCD & Monitoring Connections
Covers DRED port connections, RCD requirements, and inverter monitoring setup.
4.12 OCPD, Earth Fault Alarm & LED Indicators
Explains over-current protection, earth fault alarms, and LED status indicators.
Operation
5.1 Initial Display
Guides users through the initial language setting upon powering up the inverter.
5.2 Main Menu & Information
Describes the main menu structure and how to view inverter information.
5.4 Settings & Time/Date Configuration
Details how to configure inverter settings, including time and date.
5.4.2 Set Address & 5.4.3 Set Language
Explains how to set the inverter's slave address and system language.
5.5 Advanced Information & Alarm Messages
Provides access to detailed information, including alarm messages.
5.5.2-5.5.5 Running Message to Daily Energy
Details various operational data points like running messages, version, and daily energy.
5.5.6-5.5.9 Monthly to Warning Messages
Covers monthly energy, yearly energy, total energy, and warning messages.
5.6 Advanced Settings & Select Standard
Describes restricted advanced settings and selecting grid standards.
5.6.2 ON/OFF & 5.6.3 Calibrate
Explains how to start/stop generation and calibrate the inverter.
5.6.4 Reset Password, 5.6.5 Restart HMI & 5.6.6 Storage Energy Set
Covers password reset, HMI restart, and storage energy configuration.
5.6.6.1 Control Parameter & 5.6.6.2 Battery Select
Details control parameters and selecting compatible battery modules.
5.6.6.5 Battery Wakeup & 5.6.7 Export Power Set
Explains battery wakeup function and setting export power control.
5.6.6.3 Meter Set & 5.6.6.4 Storage Mode Select
Covers meter selection and choosing between different storage modes.
5.6.7.1 Backflow Power & 5.6.7.2 ON/OFF
Details backflow power settings and enabling/disabling export power functions.
5.6.7.3 FailSafe ON/OFF, 5.6.8 HMI Update, 5.6.9 DSP Update, 5.6.10 Baud Rate RS485
Covers failsafe settings, HMI/DSP updates, and RS485 baud rate.
5.6.11 Special Setting & 5.6.11.1 AFCI Set
Explains special settings, including the AFCI function and its configuration.
5.6.11.2 EPS Mode
Details the EPS Mode, which requires an external Solis NPS switching box.
Commissioning & Shutdown
6.1 Preparation, Procedure & Shutdown
Covers commissioning preparation, procedure, and shutdown steps.
Appendix
10.1 Battery Terminal Assembly
Provides detailed instructions for assembling battery power cable connectors.
10.2 Three Phase Meter & 10.3 Special Back-up Connections
Covers three-phase meter connections and special back-up port configurations.
10.4 Working Mode Description
Explains the logic and settings for different working modes like Self-Use and Feed-In.
10.5 Advanced Settings & Working Mode Set
Details advanced settings, grid code selection, and working mode configurations.
10.5.2-10.5.5 Power Rate Limit to DRM Settings
Covers power rate limits, frequency derating, voltage settings, and DRM configurations.
10.6 Built-In DC Isolator Specification
Specifies the ratings and standards for the inverter's built-in DC isolator switch.

Table of Contents