48
IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User's Guide
Attention:
Static electricity that is released to internal server components
when the server is powered-on might cause the server to halt, which might
result in the loss of data. To avoid this potential problem, always use an
electrostatic-discharge wrist strap or other grounding system when you work
inside the server with the power on.
2. Remove the server cover (see "Removing the cover and bezel" on page 30).
3. Make sure that the memory hot-swap enabled LED is lit. If the LED is not lit,
enable memory mirroring (see "Active Memory" on page 43).
Release latch
4. Remove the memory card:
a. Slide the orange release latch to the unlocked position.
Attention:
v When you move the memory card, do not allow it to touch any
components or structures inside the server.
v To avoid loss of data, make sure that the memory port power LED is off
before you remove the memory card.
b. Open the retention levers on the top of the memory card.
c. While you hold the retention levers open, lift the memory card out of the
server.
5. Place a memory card on a flat, static-protective surface, with the DIMM
connectors facing up.
Attention:
To avoid breaking the DIMM retaining clips or damaging the
DIMM connectors, open and close the clips gently.
6. Open the retaining clip on each end of the DIMM connector and remove the
DIMM or DIMMs that you are replacing.
7. Touch the static-protective package that contains the DIMM to any unpainted
metal surface on the outside of the server; then, remove the DIMM from the
package.
8. Turn the DIMM so that the DIMM keys align correctly with the slot.

Hide quick links: