Siemens SIMATIC NET SCALANCE XP208 Operating Instructions Manual

Siemens SIMATIC NET SCALANCE XP208 Operating Instructions Manual

Industrial ethernet switches

Advertisement

Quick Links

SIMATIC NET
Industrial Ethernet switches
SCALANCE XP-200
Operating Instructions
03/2021
C79000-G8976-C428-08
Introduction
Safety notices
Recommendations on
network security
Description of the device
Installation
Connecting up
Upkeep and maintenance
Technical specifications
Dimension drawings
Approvals
1
2
3
4
5
6
7
8
9
A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SIMATIC NET SCALANCE XP208 and is the answer not in the manual?

Questions and answers

Summarization of Contents

Introduction
Purpose of the Operating Instructions
Explains the manual's goal and scope, focusing on installation and connection.
Documentation on configuration
Points to related configuration manuals for detailed setup instructions.
Security information
Crucial security advice, recommendations, and measures for network protection.
Recycling and disposal
Environmental guidelines and procedures for product disposal and recycling.
Safety notices
Read the safety notices
General safety guidance and critical warnings to observe during the device's lifecycle.
Safety notices on use in hazardous areas
Specific safety precautions for installation and operation in hazardous environments.
Recommendations on network security
Information security
Basic security measures and best practices for information protection.
Physical access
Measures to secure physical access to the device and its data.
Software (security functions)
Software-related security measures, updates, and protocol management.
Passwords
Best practices for creating and managing strong, secure passwords.
Certificates and keys
Using certificates and keys for secure communication and authentication.
Secure/non-secure protocols and services
Guidelines for managing network protocols to enhance security.
Interfaces security
Securing device interfaces against unauthorized access and intrusion.
Available protocols
Details on available network protocols and their security configurations.
Description of the device
4.1 Product overview
General product description, variants, and key features.
Article numbers
Lists product identifiers for different device models.
Components of the product
Details what is included in the product package.
Accessories
Lists optional add-on components and their specifications.
4.2 Device views
Visual identification of device parts, ports, and interfaces.
4.3 LED display
Explains the meaning of device status indicators (LEDs) for diagnostics.
4.4 RESET button
Describes the function and operation of the device reset button.
4.5 SELECT / SET button
Describes the function and operation of the select/set button for mode selection.
4.6 C-PLUG
Details on the C-PLUG configuration memory module and its usage.
4.7 Power over Ethernet (PoE)
Functionality and specifications for Power over Ethernet capabilities.
Installation
5.1 Safety notices for installation
Critical safety guidelines and precautions for device installation.
5.2 Types of installation
Overview of available mounting methods for the device.
5.3 Wall mounting
Detailed procedures and steps for mounting the device on a wall.
5.4 Wall mounting
Alternative procedure for wall mounting, potentially back-mounting.
5.5 Rack mounting
Instructions and steps for mounting the device in a standard rack.
Connecting up
6.1 Safety when connecting up
Crucial safety instructions and precautions before connecting the device.
6.2 Industrial Ethernet
Connecting the device to an Industrial Ethernet network.
Ethernet ports
Details on Fast and Gigabit Ethernet interfaces and their pin assignments.
Autonegotiation
Automatic negotiation of transmission speed and port operating modes.
6.3 24 VDC power supply
Connecting the device to a 24 VDC power source.
6.4 54 VDC power supply
Connecting the device to a 54 VDC power source.
6.5 Signaling contact
Connecting the signaling contact for error reporting and status indication.
6.6 Serial interface
Connecting and using the serial console interface for device access.
6.7 Functional ground
Proper connection of the functional ground for EMC compliance.
Upkeep and maintenance
7.1 Downloading new firmware using TFTP without WBM and CLI
Procedure for updating device firmware using TFTP without WBM or CLI.
7.2 Restoring the factory settings
Procedures to reset device parameters and configurations to factory defaults.
Technical specifications
8.1 Technical specifications SCALANCE XP208 and SCALANCE XP208EEC
Detailed technical specifications for SCALANCE XP208 and XP208EEC models.
8.2 Technical specifications of the SCALANCE XP208P0E EEC
Detailed technical specifications for the SCALANCE XP208P0E EEC model.
8.3 Technical specifications SCALANCE XP216 and SCALANCE XP216EEC
Detailed technical specifications for SCALANCE XP216 and XP216EEC models.
8.4 Technical specifications of the SCALANCE XP216P0E EEC
Detailed technical specifications for the SCALANCE XP216P0E EEC model.
8.5 Cable lengths
Permitted cable lengths for various Ethernet cable types used with the device.
8.6 Switching properties
Device's network switching characteristics, including latency and frame handling.
Dimension drawings
Front view of the SCALANCE XP208
Dimensions and mounting layout for the SCALANCE XP208 model.
Front view of the SCALANCE XP216
Dimensions and mounting layout for the SCALANCE XP216 model.
Side view of the SCALANCE XP-200
Overall depth and width dimensions of the SCALANCE XP-200 device.
Approvals
EC declaration of conformity
Compliance with EU directives and harmonized European standards.
ATEX (explosion protection directive)
Safety requirements and certifications for use in explosive atmospheres.
IECEx
International certification for hazardous area equipment and protection types.
EMC directive (electromagnetic compatibility)
Compliance with electromagnetic compatibility regulations.
RoHS
Compliance with the directive restricting hazardous substances.
FM
Approval for specific hazardous location classifications (Factory Mutual).
cULus Approval for Information Technology Equipment
Safety certification for Information Technology Equipment by cULus.
Railway approval
Compliance with standards for railway rolling stock applications.
Note for Australia - RCM
Australian regulatory compliance marking and standards.

Table of Contents