Source Learning; Link Aggregation Affecting Other Traffic; Problems Creating A Group; Problems Deleting A Group - Alcatel OmniSwitch 6624 Troubleshooting Manual

Alcatel internetworking, inc. switch troubleshooting guide
Hide thumbs Also See for OmniSwitch 6624:
Table of Contents

Advertisement

Troubleshooting Link Aggregation

Source Learning

When one of the primary links go down, the filtering database is purged and the process of learning the
source addresses is started again. The next available port is chosen to be the primary port. If the port that
goes down happens to be a secondary port, the MAC addresses learned on that particular port are re-
assigned to other ports evenly.

Link Aggregation Affecting Other Traffic

Note that depending on what software and hardware is being used, enabling link aggregation on a port
could affect other traffic on the same NI. Please call Customer Support if you suspect this to be the case.

Problems Creating a Group

Note that if there are problems creating a linkagg group or adding ports to an existing group the below
should be considered:
Ports involved in a link aggregate need to all be of the same line speed.
Mobile ports can not be a part of a link aggregate.
There are a maximum of 32 aggregate groups allowed on an OmniSwitch 7700/7800/8800switch, 30
on a stack of OmniSwitch 6624/6648 switches, and 8 on a single OmniSwitch 6624/6648 switch. The
number goes down on OmniSwitch 7700/7800/8800 switches depending on the size of the aggregate,
see below.

Problems Deleting a Group

To delete a static link aggregate, the attached ports must first be deleted with the no static agg CLI
command. To delete a dynamic (802.3AD) aggregate, use the no lacp linkagg CLI command.
OmniSwitch Troubleshooting Guide
September 2005
Troubleshooting a Link Aggregation Failure
page 7-5

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents