SPECIFICATIONS AND FEATURES
MODEL
Nominal DC Input Voltage
AC Output Voltage (RMS)
Nominal Frequency
Continuous Power @ 25 °Ÿ C
Continuous Current @ 25 °Ÿ C
Maximum Current (100 mSec Record)
Maximum Power (Light Bulb Rating)
Efficiency (peak)
DC INPUT REQUIREMENTS
Search Mode
On Mode (no load - idle)
At Full Rated Power
Input Voltage Range
Low Battery Cutout (w/out SB Option)
High Voltage Cutout
AC OUTPUT CHARACTERISTICS
AC Output Waveform
Voltage Regulation
Power Factor Allowed
Frequency Regulation
ENVIRONMENTAL LIMITATIONS
Enclosure Type
Specified Temperature Range
Allowed Operating Temperature Range
Dimensions - Inverter Only
Dimensions - Shipping
Mounting
Weight - Inverter only
Weight - Shipping
STAND-BY (SB) OPTION
Automatic AC Transfer Relay
Maximum Battery Charging Rate
3-stage Charger Regulation Method
Selectable Low Battery Cutout
ADDITIONAL OPTIONS
Battery Temperature Sensor
Remote Control Panel
Rugged:
Designed for maximum service, all UX models offer powder coated chassis,
stainless fasteners, conformal coated circuit boards and gold plated connectors. AC wiring
terminates cleanly inside the wall or shelf mountable chassis.
The Bottom line:
The Trace UX series of compact inverters provides quiet, dependable
power whenever and wherever you need it, at a price you can afford.
100
90
80
70
60
50
40
0
500
1000
1500
Output in Watts
Typical Efficiency
5916 195th St. N.E. ARLINGTON, WA. USA 98223 Phone (360) 435-8826 Fax (360) 435-2229 Web: www.traceengineering.com
Model UX Series
(rev. 1.0)
UX512E
UX612
12 VDC
12 VDC
230 VAC
120 VAC
50 HZ
60 HZ
500 VA
600VA
2 amps AC
5 amps AC
10 amps AC
18 amps AC
2500 W
2500 W
92% max
92% max
0.022 A (0.4W)
0.022 A (0.4W)
0.400 A (5.0W)
0.400 A (5.0W)
54 amps
63 amps
10.8 to 15.5 VDC
10.8 to 15.5 VDC
9.5 VDC
9.5 VDC
15.7 VDC
15.7 VDC
Indoor, ventilated, steel chassis with powdercoat finish
32 °Ÿ F to 104 °Ÿ F (0 °Ÿ C to +40 °Ÿ C ) (output will meet specified tolerances)
-40 °Ÿ F to 140 °Ÿ F (-40 °Ÿ C to +60 °Ÿ C ) (output may not meet specified tolerances)
10.5" (26.7 cm) high, 15.5" (39.4 cm) wide, 6" (15.2 cm) deep (when wall mounted)
20.5" (52 cm), 27" (69 cm) 15.5" (40 cm)
25 lbs (11.4 kg)
25 lbs (11.4 kg)
30 lbs (13.6 kg)
30 lbs (13.6 kg)
30 amps AC
30 amps AC
25 amps DC
25 amps DC
Bulk (constant current), Absorption (constant voltage) and Float (maintenance voltage & current)
9.5 VDC (allows deep discharge) or 11.8 VDC ( for use with starting or shallow cycle batteries)
BTS/15: 15 foot plug-in battery temperature sensor with phone jack (can be extended)
RC8/50: 50 foot On/Off remote with LED status indicator
RC8/100: 100 foot On/Off remote with LED status indicator
Note: All specifications are subject to change without notice
4,000
1412
1112
3,000
612
2,000
1,000
0
TIME IN MINUTES
Power vs. Time
UX1112
UX1112E
12 VDC
120 VAC
230 VAC
60 HZ
1100 VA
9 amps AC
22 amps AC
3000 W
90% max
0.045 A (0.5W)
0.045 A (0.5W)
0.450 A (5.5W)
0.450 A (5.5W)
120 amps
10.8 to 15.5 VDC
10.8 to 15.5 VDC
9.5 VDC
15.7 VDC
Modified sinewave
+/- 5% Maximum, +/- 2.5% Typical
-1 to 1
+/- 0.01% (crystal regulated)
Wall or Shelf Mount
30 lbs (13.6kg)
35 lbs (15.9 kg)
35 lbs (15.9kg)
40 lbs (18.2 kg)
30 amps AC
50 amps DC
Battery Charger Method
UX1412
12 VDC
12 VDC
120 VAC
50 HZ
60 HZ
1100 VA
1400 VA
5 amps AC
12 amps AC
11 amps AC
30 amps AC
3000 W
3400 W
90% max
92% max
0.060 A (0.7W)
0.600 A (7 W)
120 amps
153 amps
10.8 to 15.5 VDC
9.5 VDC
9.5 VDC
15.7 VDC
15.7 VDC
35 lbs (15.9 kg)
40 lbs (18.2 kg)
30 amps AC
30 amps AC
50 amps DC
50 amps DC
U L
POWER CONDITIONING UNITS FOR
USE
IN
PHOTOVOLTAIC
®
SYSTEMS— STANDARD UL 1741
U L
COMMERCIAL AND INDUSTRIAL
®
C
POWER SUPPLIES—CERTIFIED TO
CAN/CSA-C22.2 NO. 107.1-M91
LISTED
39FL
THE POWER COMPANY
ENGINEERING
Available From:
POWER
Rev# 4/98