Autotransformer For 240 Vac Applications (T240); Inverter Stacking Control - Series (Isc-S) Cable; Figure 2-13 T240 Auto-Transformer; Figure 2-14 Isc-S Cable - Xantrex SW 2524 - REV A Owner's Manual

Sine wave plus inverter/charger
Table of Contents

Advertisement

Autotransformer for 240 VAC Applications (T240)

Inverter Stacking Control – Series (ISC-S) Cable
976-0043-01-01
The T240 allows a single inverter to increase it's output voltage from
120 volts to 240 volts or it will take 240 Vac from a generator and "step-
down" the voltage to 120 Vac for the single inverter. For step-up and step-
down functions, two T240s will be required. Using a T240
Autotransformer optimizes the generator output of smaller generators
(< 8 kW) and improves charging time.

Figure 2-13 T240 Auto-transformer

The ISC-S cable is a special communications cable that allows two
Wave Plus
inverters to be connected together in "series" to provide power
to both 120 Vac loads and 240 Vac loads.
See the ISC-S Owner's Guide for more information on stacked inverter
applications.

Figure 2-14 ISC-S Cable

Additional/Optional Equipment Considerations