6-8
4. With the imaging guide still out of the scanner, locate the glass
camera cover between and below the LED lamps.
Imaging guide removed
Lamp
LEDs
5. Using a clean dry swab, gently wipe across the glass camera cover
to remove any dirt and dust particles. Do not spray any solvent on
the swab unless a dry swab will not remove the residue on the
glass. If you need to use solvent, spray the solvent on the swab. Do
not spray solvent in or around the internal components of the
scanner.
6. When the camera cover is clean, re-insert the cleaned imaging
guide into the scanner by holding the frame of the imaging guide so
that the fastening clips are on the back side of the imaging guide.
Slide the guides under the transport tray towards the feeder table
and ease the back side of the imaging guide into position.
Fastening clips
Five guides slide underneath the transport tray
7. Repeat Steps 2 - 6 to clean the bottom imaging guide and bottom
camera cover.
8. When finished, close the scanner cover.
Imaging
guide
A-61662 October 2011