Loria 6000
Air/water heat pump
single service split system
Loria 6010
Loria 6004
Loria 6006
Loria 6008
Document No. 1634-4 ~ 26/04/2016
FR
NL
DE
EN
ES
PT
IT
PT
User manual
for professionals
and users
to be kept by the user
for future reference
atlantic-comfort.com
Subject to modifications without notice.
Document not binding.
PL
PT

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Loria 6006 and is the answer not in the manual?

Questions and answers

Summary of Contents for Atlantic Loria 6006

  • Page 1 Document No. 1634-4 ~ 26/04/2016 Air/water heat pump single service split system Loria 6010 User manual for professionals and users to be kept by the user for future reference Loria 6004 Loria 6006 Loria 6008 atlantic-comfort.com Subject to modifications without notice. Document not binding.
  • Page 2: Table Of Contents

    Loria 6000 heat pump Contents Safety instructions Overall view of the installation Precautions and warnings regarding your installation 4 Floor heating systems The outdoor unit Fan-coil heaters with integrated control system 4 The hydraulic unit Domestic hot water (DHW) The controller End of life of the device The radiators Overall view of the installation...
  • Page 3: Safety Instructions

    Loria 6000 heat pump 1 Safety instructions " Please comply with the following instructions in order to avoid any risk of injury or inappropriate use of the appliance • Commissioning " Do not switch the appliance on until all filling operations are complete. "...
  • Page 4: Overall View Of The Installation

    Loria 6000 heat pump 2 Overall view of the installation Precautions and warnings 2 1 5 Floor heating systems regarding your installation New floor heating systems must be initially heated slowly to avoid cracking Check with your installer that 2 1 1 The outdoor unit this initial heating procedure has been performed before using your heating system as you see fit.
  • Page 5: The Outdoor Unit

    Loria 6000 heat pump End of life of the device Overall view of the installation The apparatus must be dismantled and recycled by a Your heat pump has been configured by your installer. It specialised service provider is composed of the following main elements: The apparatus must never be disposed of with - The outdoor unit is positioned, as its name indicates, household waste, large objects or in a landfill.
  • Page 6: Operation Of The Installation

    Loria 6000 heat pump 3 Operation of the installation User interface and description of the display figure 2 - User interface Ref. Functions - Definition of the functions • SELECT - Browse and select the available uses • MODE - Browse and select the mode for the pre-selected use •...
  • Page 7 Loria 6000 heat pump • Description of the display (user interface) Icons Definitions Access the User settings Use for heating (reference to the circuit concerned Z1 or Z2) Use for DHW Use for cooling (reference to the circuit concerned Z1 or Z2) Stand-by Compressor operation Electrical back-up operation...
  • Page 8: Commissioning The Appliance

    Loria 6000 heat pump Commissioning the appliance • The installation and first commissioning of the heat pump must be performed by a qualified installer. This person will also instruct you on how to start and run the heat pump • Ensure that the installation is correctly filled with water and properly drained and that the pressure measured by the pressure gauge is sufficient (1 to 1.5 bar).
  • Page 9: Basic Display

    Loria 6000 heat pump 3 3 2 Time setting Basic display 1 - Press - The "key" icon appears, - Alternation between the "time settings" parameter (line No 1) and the time (e g 18:30) (No. 1 / 18:30): 2 - Press to change the time - The hour display flashes.
  • Page 10 Loria 6000 heat pump 3 3 3 Selecting the MODE and setting the TIME PROGRAMME depending on the USE • Selecting the USE To select the use: press the SELECT button several times Select the use to be configured. The icon flashes. Example: Heating of area 1 Description of the other uses*:...
  • Page 11 Loria 6000 heat pump • Changing the heating (or cooling*) TIME PROGRAMME The default heating time programme is set for the whole week: from 6 a m to 10 p m in comfort mode (from 10 p m to 6 a m in reduced mode) phase end of comfort heating start of comfort heating...
  • Page 12 Loria 6000 heat pump 3 3 4 Setting the temperature setpoints mode - A- Change the setpoint Example: changing the ECO setpoint Current use (heating of area 1) Current mode (PROG / comfort phase)  If necessary, press the SELECT button to display the use to be changed [E.g.: Change the setpoint for the area 2 heating use] ...
  • Page 13 Loria 6000 heat pump  User manual "1634 - EN" - 13 -...
  • Page 14 Loria 6000 heat pump Selecting the DHW* MODE and setting the DHW TIME PROGRAMME • Selecting DHW USE To select the use: press the SELECT button several times The icon flashes. • Selecting the MODE To select the mode: press the MODE button several times The icon flashes.
  • Page 15 Loria 6000 heat pump • Changing the DHW timer programme default timer programme whole week (Monday Sunday: from 12 a m to 5 a m (1 DHW heating phase) and from 2:30 p m to 5 p m (2 DHW heating phase) phase phase start of...
  • Page 16: Time Setting

    Loria 6000 heat pump 4 Regulation parameters Overview • Only the parameters accessible to the following level: - User are described in this document • The parameters accessible to the following level: - Installer … are described in the document reserved for these professional specialists Do not make any modifications to these parameters without advice from these professional specialists...
  • Page 17 Loria 6000 heat pump Configuration Basic Function or display range setting Heating time programme , circuit 2 (1) (2) Pre-selection (day / week) 1 = Monday; 2 = Tuesday… 7 = Sunday; 8 = Monday to Friday; 9 = Saturday and Sunday 10 = Monday to Sunday (modifications are applied to the whole week) phase of the selected day (start of comfort) 00:00...
  • Page 18: Information And Troubleshooting

    Loria 6000 heat pump 5 Information and troubleshooting Displaying information " Status list button calls up various information The parameter number is displayed and alternates with its value (example No 13 / 1 = HP heating status) Depending on the appliance type, the configuration and the state of operation, certain information lines may not Value...
  • Page 19 Loria 6000 heat pump Error codes Description Switched to safety mode Probable causes Minor Major error error Short circuit, sensor disconnected HP outgoing flow sensor error or cut off Defective sensor Other (T5) error Short circuit, sensor disconnected HP return flow sensor error (T6). or cut off Defective sensor Other error Initial temperature >...
  • Page 20: Maintenance

    Loria 6000 heat pump Outdoor unit errors In the event of an outdoor unit error: - The user interface displays the error code "Er 66" - View the information menu - Information " No. 18" specifies the error code for the outdoor unit " xx"...
  • Page 21 Loria 6000 heat pump 7 Room thermostat UA55 (optional) °C User manual "1634 - EN" - 21 -...
  • Page 22: Programme

    Loria 6000 heat pump Room thermostat* and description of the display Description of the display: If the installation is equipped with a room thermostat, the time programme does not appear on the user interface The time programme is only managed using the room thermostat in the area considered Refer to the room 00:00 1 2 3 4 5 6...
  • Page 23: Standby Mode

    Loria 6000 heat pump 7 2 1 Setting the time and day Basic display Setting the time 18:30 1 - Press to reach the time and day mode prog boost settings menu, - The hour display flashes. 19:32 2 - Press to set the time [e g 6:30 p m ->...
  • Page 24 Loria 6000 heat pump 7 2 3 Automatic mode: setting the TIME PROGRAMME and the temperature setpoint - The default time programme is set  for the whole week: [Day 1 to 7]  6 phases: [6 a m (20 °C)] - [8 a m (18 °C)] - [11:30 a m (20 °C)] - [1:30 p m (18 °C)] - [5:00 p m (20 °C)] and [10 p m (18 °C)] Ph.
  • Page 25 Loria 6000 heat pump Copy a phase to the next day tip (e.g.: copy phase 1 - 7:30 a.m. - 20.5 °C to day 7). Tip: to copy identical phases: 07:30 - Press and "hold" the knob for more than 3 seconds to 2 3 4 5 6 copy the time programme phase to the next day 20.5...
  • Page 26: Exemption Function - "Boost" Button

    Loria 6000 heat pump 7 2 6 Standby mode 1 - Press the mode button to select the standby mode (until all icons disappear) 19:32 mode prog boost (press release) 7 2 7 Exemption function – "Boost" button Press the boost button to access the exemption (e.g.: heating exemption).
  • Page 27 Loria 6000 heat pump Appliance shutdown 7 3 1 Stopping heating In the event of appliance shutdown for a known period of time, set the appliance to holiday mode: - Without room thermostat, see § 3.3.3, page 10 - With room thermostat, see § 7.2.5, page 25 In the event of shutdown for an extended period or an unknown period of time, set the appliance to off or...
  • Page 28 - The eco-design directive sets efficiency thresholds and prohibits the sale of any product with an efficiency lower than the set thresholds. - According to the labelling directive, energetic efficiency shall be displayed to encourage end users to purchase energy-efficient products. ERP Specifications Trade name / Product name: atlantic / Loria 6004 Loria 6006 Loria 6008...
  • Page 29 Loria 6000 heat pump Trade name / Product name: atlantic / Loria 6004 Loria 6006 Loria 6008 Loria 6010 Reference 522911 522912 522913 522914 Heating ranges 35°C 55°C 35°C 55°C 35°C 55°C 35°C 55°C Supplementary heater Rated heat output Type of energy input...
  • Page 30 Loria 6000 heat pump Package sheet Outdoor sensor included in the combined package Controller class Contribution to seasonal efficiency Room appliance references 076310 Controller class Contribution to seasonal efficiency " range 35°C < 55% ≥ 55% ≥ 59% ≥ 61% ≥ 100% ≥ 107% ≥ 115% ≥ 123% ≥ 150% ≥ 175% Product name Loria 6004 Loria 6006...
  • Page 31 Loria 6000 heat pump  User manual "1634 - EN" - 31 -...
  • Page 32 Please contact your installer or local representative for more information * Depending on the national regulations of each member state Date of commissioning: atlantic-comfort.com Société Industrielle de Chauffage SATC - BP 64 - 59660 MERVILLE - FRANCE Address of your heating installer or customer service.