Download Print this page

Warmington 900 Installation, Operating, & Maintenance Instructions

Free-standing eclipse open fire wood burner
Hide thumbs Also See for 900:

Advertisement

Quick Links

Industries 1994 LTD
Ensure That You Have The Correct
PO Box 58652 Greenmount, Auckland
and current Installation Details For
Fire and flue system to comply to AS/NZS 2918
WWW.Warmington.co.nz
The Size of The Warmington Fire
That is to be installed.
Keep these Instructions for future reference.
Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification
Warmington
780-780T-900
Free-Standing Eclipse Open Fire
Wood Burner
Installation, Operating & Maintenance
Instructions
Effective from 1
September 2005
st
Created on 10/07/2006 10:09 a.m.
Page 1 of 15
S:\data\Word\spec. sheets\eclipse-crystal eclipse\Free Standing Eclipse 11-07-06.doc
All dimensions are in millimetres mm
All dimensions are minimums

Advertisement

loading
Need help?

Need help?

Do you have a question about the 900 and is the answer not in the manual?

Questions and answers

Summary of Contents for Warmington 900

  • Page 1 The Size of The Warmington Fire That is to be installed. Keep these Instructions for future reference. Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification Warmington 780-780T-900 Free-Standing Eclipse Open Fire Wood Burner Installation, Operating &...
  • Page 2 That is to be installed. Keep these Instructions for future reference. Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification Points to consider prior to installation: • Location of the fire in the home. The position of the fire will have an effect on the distribution of the heat through the home.
  • Page 3: Important Notes

    The Size of The Warmington Fire That is to be installed. Keep these Instructions for future reference. Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification INSTALLATION ORDER OF OPERATION Prior to Construction and Installation Important Notes: Install to AS/NZS 2918: 2001.
  • Page 4 That is to be installed. Keep these Instructions for future reference. Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification Burn Control and Operation of your Warmington Fire. Correct Operation of Wood Heating Appliances Simply by burning your wood heater correctly, you can improve efficiency and reduce air pollution.
  • Page 5 Keep these Instructions for future reference. Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification Next crumple half a dozen sheets of newspaper and put them in the firebox. The amount of newspaper you need will depend on the firebox size, and the dryness and fineness of the kindling you are using.
  • Page 6 If there is no charcoal and only very fine ash then you are doing an excellent job. Warmington wood-burning appliances work best when a small amount of ash is left approximately 25mm deep in the firebox after cleaning, this aids with stable burning.
  • Page 7 Keep these Instructions for future reference. Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification When You Have Mastered the Techniques for Efficient Wood Burning, Here is what you should see: •...
  • Page 8 Keep these Instructions for future reference. Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification Improper appliance firing technique: When a wood fire is starved for air it smoulders, producing a relatively cool, smoky fire.
  • Page 9 That is to be installed. Keep these Instructions for future reference. Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification 1. WARNING; ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY IS CONSIDERED AS BREACHING AS/NZS 4013.
  • Page 10 Keep these Instructions for future reference. Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification Although the energy content of dry wood per kilogram is almost the same regardless of species, softwoods and hardwoods burn differently because of differences in density.
  • Page 11 The installation and construction of the flue system must comply with ASNZS 2918. The Warmington Open fires requires a Warmington Tested and approved flue system only, as tested to ASNZS 2918. The tested flue system should not be modified in any way without the written approval of the manufacturer .Any additional flue components to the flue system must comply with...
  • Page 12 Keep these Instructions for future reference. Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification On special order a wetback model can be supplied. The wetback sits along the back of the firebox. The inlet and outlet are to the side of the fireplace and require standard 25mm pipe connections to the threaded brass pipe of the wetback.
  • Page 13 The Size of The Warmington Fire That is to be installed. Keep these Instructions for future reference. Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification Caitec™ Caitec™ Technology Warmington’s innovative solution to introduce...
  • Page 14: Firebox Dimensions

    The Size of The Warmington Fire That is to be installed. Keep these Instructions for future reference. Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification Firebox Dimensions Firebox and Flue Air flow thru 2 x Ø100 vents...
  • Page 15 That is to be installed. Keep these Instructions for future reference. Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification Plan View of Cabinet Clearances (Straight Position) Free standing fire box.