Siemens SINAMICS G120M Manual

Siemens SINAMICS G120M Manual

Speed control of a startdrive with tia portal via profibus dp with safety integrated (via terminal) and hmi

Advertisement

SINAMICS G:
Speed Control of a
G110M/G120
(Startdrive) with
S7-1200 (TIA Portal)
via PROFIBUS DP with
Safety Integrated (via
Terminal) and HMI
SINAMICS G110M, G120 / SIMATIC S7-1200
https://support.industry.siemens.com/cs/ww/en/view/70155469
Siemens
Industry
Online
Support

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SINAMICS G120M and is the answer not in the manual?

Questions and answers

Summarization of Contents

Legal Information
Use of Application Examples
Illustrates automation tasks using components like text, graphics, and software modules.
Disclaimer of Liability
Siemens disclaims liability for defects, errors, or damages arising from application examples.
Security Information
Details industrial security functions and recommendations for secure plant operation.
Task
Overview of the Automation Task
Provides a graphical overview of the automation task involving SINAMICS and SIMATIC components.
Requirements for the Automation Task
Lists essential requirements for successful automation task implementation.
Solution
Solution Overview
Presents an example of PROFIBUS connection between SINAMICS G120C and SIMATIC S7-1212C.
Description of the Core Functionality
Explains the communication setup and data exchange between SINAMICS G120 and SIMATIC S7-1200.
Hardware and Software Components Used
Lists the specific hardware and software components required for the application example.
Standard Software Components
Details the standard software components necessary for the project, like TIA Portal and Startdrive.
Setting Up and Commissioning the Application
Wiring
Illustrates the hardware setup and connections for the application example.
IP and PB Addresses
Specifies the IP and PROFIBUS addresses used for communication between devices.
PG/PC Settings
Details the necessary IP address configuration on the PG/PC for establishing a connection.
Setting the PROFIBUS Address at the G120 DP
Explains how to set the PROFIBUS address on the SINAMICS G120 using DIP switches.
Loading the Software
Guides through the process of loading STEP 7, drive, and HMI configurations.
Operating the Application
Preconditions
Outlines the necessary prerequisites for controlling the SINAMICS drive via HMI or watch table.
Operation via Digital Inputs
Describes how to control the SINAMICS drive's operation using digital inputs.
Monitoring and Parameter Access via Operator Panel
Explains how to navigate HMI screens for monitoring drive status and accessing parameters.
Parameter Access
Details the procedure for reading and writing drive parameters via the operator panel.
Fault Buffer
Describes how to view current and acknowledged faults saved in the SINAMICS converter.
Operator Control and Monitoring via Monitoring Table
Explains how to use watch tables in TIA Portal for monitoring and control without an HMI.
Functional Mechanisms of this Application
Program Overview
Provides an overview of the program structure, including function blocks and data blocks.
Functionality of Process Data Exchange
Explains the cyclic data exchange between the controller and the SINAMICS converter.
Parameter Access Functionality
Details how to access and manage parameters asynchronously.
Configuration and Settings
Creating the Project Configuration
Guides through the process of creating a new project and configuring hardware components in TIA Portal.
Change Device of SINAMICS G120
Describes how to change the device type, firmware version, or power module of a SINAMICS G120.
Safe Torque Off (STO) with Safety Integrated
Explains the configuration of the Safe Torque Off (STO) safety function.
Comments on Programming the SIMATIC S7-1200
Provides programming details for instructions like DPRD_DAT/DPWR_DAT in SIMATIC S7-1200.