This system has been tested according to ANSI/NSF 42/53 for the reduction of the substances listed below. The concentration of the
indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water
leaving the system, as specified in ANSI/NSF 42/53.
Substance Reduction
NSF Reduction
Aesthetic Effects
Requirements
Chlorine Taste/Odor
≥50%
Particulate Class 1*
≥85%
Contaminant
NSF Reduction
Reduction
Requirements
Lead: @ pH 6.5
0.01mg/L
Lead: @ pH 8.5
0.01mg/L
Mercury: @ pH 6.5
0.002 mg/L
Mercury: @ pH 8.5
0.002 mg/L
Benzene
0.005 mg/L
p-dichlorobenzene
0.075 mg/L
Toxaphene
0.003 mg/L
Atrazine
0.003 mg/L
2, 4-D
0.07 mg/L
Asbestos
99%
Cysts‡
99.95%
Turbidity
0.5 NTU
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 63°F
(17.2°C).
It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
The filter monitor system measures the amount of water that
passes through the filter and alerts you to replace the filter.
When 90% of the filter's rated life is used, the filter indicator
light changes from green to yellow. When 100% of the filter's
rated life is used, the filter indicator light changes from yellow
to red, and it is recommended that you replace the filter. Use
replacement cartridge AFF5. See www.everythingdacor.com.
The product is for cold water use only.
* Class I particle size: >0.5 to <1 um
** Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
† These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.
†† Fibers greater than 10 um in length
‡ Based on the use of Cryptosporidium parvum oocysts
® NSF is a registered trademark of NSF International.

Product Data Sheets

Base Grille Water Filtration System (Water Filter)
Model WF-LC400V/LC400V Capacity 400 Gallons (1514 Liters)
Tested and certified by NSF International against ANSI/NSF Standard 42 for
the reduction of Chlorine Taste and Odor, Particulate Class I*; and against
ANSI/NSF Standard 53 for the reduction of Lead, Mercury, Atrazine, Benzene,
Toxaphene, p-dichlorobenzene, 2, 4-D, Cysts, Turbidity and Asbestos.
Average
Influent
2.1 mg/L
5,366,667/mL
Average
Influent Challenge
Influent
Concentration
0.152 mg/L†
0.15 mg/L ± 10%
0.143 mg/L†
0.15 mg/L ± 10%
0.0061 mg/L
0.006 mg/L ± 10%
0.0057 mg/L
0.0058 mg/L ± 10%
0.0162 mg/L
0.015 ± 10%
0.220 mg/L
0.225 ± 10%
0.014 mg/L
0.015 ± 10%
0.0086 mg/L
0.009 mg/L ± 10%
0.197 mg/L
0.210 ± 10%
26 x 107
107 to 108 fibers/L††
111,000/mL
50,000/L min.
11.00 NTU
11 ± 1 NTU
Influent Challenge
Maximum
Concentration
Effluent
2.0 mg/L ± 10%
0.06 mg/L
At least 10,000
4,100/mL**
particles/mL
Maximum
Effluent
0.001 mg/L
0.001 mg/L
0.0004 mg/L
0.0008 mg/L
0.0005 mg/L
0.0005 mg/L
0.0014 mg/L
0.0005 mg/L
0.058 mg/L
0.18 x 107 mg/L 0.18 x 107 mg/L
1 mg/L
0.40 NTU
Application Guidelines/Water Supply Parameters
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
18
Average
Minimum %
Effluent
Reduction
0.05 mg/L
97.1%
2,300/mL
99.3%
Average
Minimum %
Effluent
Reduction
0.001 mg/L
99.34%
0.001 mg/L
99.30%
0.0003 mg/L
93.5%
0.00051 mg/L
85.8%
0.001 mg/L
96.3%
0.0005 mg/L
99.7%
0.001 mg/L
90%
0.0005 mg/L
94.25%
0.0137 mg/L
70.6%
99.93%
1 mg/L
99.99%
0.35 NTU
96.4%
City or Well
30 - 120 psi (207 - 827 kPa)
33° - 100°F (0.6° - 37.8°C)
0.5 GPM (1.89 L/min.) @ 60 psi.
Average %
Reduction
97.6%
99.9%
Average %
Reduction
99.34%
99.30%
96.7%
91.2%
96.3%
99.7%
92.96%
94.25%
93.06%
99.93%
99.99%
96.8%

Advertisement