This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The
concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the
permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.
Substance Reduction
NSF Reduction
Aesthetic Effects
Requirements
Chlorine Taste/Odor
50% reduction
Particulate Class I
85% reduction
Contaminant
NSF Reduction
Reduction
Requirements
Lead: @ pH 6.5
0.010mg/L
Lead: @ pH 8.5
0.010mg/L
Mercury: @ pH 6.5
0.002 mg/L
Mercury: @ pH 8.5
0.002 mg/L
Benzene
0.005 mg/L
O-Dichlorobenzene
0.6 mg/L
Toxaphene
0.003 mg/L
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.85 gpm (3.2 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 200 gallons (757 liters).
„ It is essential that operational, maintenance and filter
replacement requirements be carried out for the product to
perform as advertised.
„ Use replacement filter P2RFGG2, Dacor part # AFF6. Visit
www.everythingdacor.com or call 1-800-253-1302 (In Canada
call 1-800-807-6777).
Style 1 – When the filter indicator reads 10%, order a new
filter. When the indicator reads 0%, it is recommended that
you replace the filter.
Style 2 – When the filter indicator changes from green to
yellow, order a new filter. When the indicator changes from
yellow to red, it is recommended that you replace the filter.
Style 3 – When the water filter status display changes from
"GOOD" to "ORDER," order a new filter. When the filter
indicator reads "REPLACE," it is recommended that you
replace the filter.
Style 4 – Touch FILTER to check the status of your water filter.
If the filter indicator light is yellow, order a new filter. If the filter
indicator light is red, it is recommended that you replace the
filter.
„ Change the water filter cartridge every 6 months. If the water
flow to the water dispenser or ice maker decreases noticeably
before 6 months have passed, replace the water filter cartridge
more often.
* Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
® NSF is a registered trademark of NSF International.
Manufactured for Whirlpool Corporation (Benton Harbor, MI) by Kemflo International (Pingtung, TW)

Product Data Sheets

Base Grille Water Filtration System
Model P2RFGG2/P2WG2L, P2WG2, P1WG2L, P1WG2
Capacity 200 Gallons (757 Liters)
System tested and certified by NSF International against NSF/ANSI
Standard 42 for the reduction of Chlorine Taste and Odor, Particulate
Class I; and against NSF/ANSI Standard 53 for the reduction of Mercury,
Benzene, Toxaphene, O-dichlorobenzene, and Lead.
Average
Influent Challenge
Influent
Concentration
2.0182 mg/L
2.0 mg/L ± 10%
1333333 #/mL
At least 10,000 particles/mL
Average
Influent Challenge
Influent
Concentration
0.1533 mg/L
0.15 mg/L ± 10%
0.1400 mg/L
0.15 mg/L ± 10%
0.0058 mg/L
0.006 mg/L ± 10%
0.0059 mg/L
0.006 mg/L ± 10%
0.0154 mg/L
0.015 ± 10%
1.7571 mg/L
1.8 mg/L ± 10%
0.015 mg/L
0.015 ± 10%
Maximum
Effluent
0.06 mg/L
6600 #/mL*
Maximum
Average
Effluent
Effluent
0.0005 mg/L
0.0005 mg/L
0.0007 mg/L
0.0006 mg/L
0.0002 mg/L
0.0002 mg/L
0.0005 mg/L
0.0003 mg/L
0.0012 mg/L
0.0006 mg/L
0.0250 mg/L
0.0066 mg/L
0.001 mg/L
0.001 mg/L
„ These contaminants are not necessarily in your water supply.
While testing was performed under standard laboratory
conditions, actual performance may vary.
„ The product is for cold water use only.
„ Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system.
„ Refer to the Warranty and Service section for the
Manufacturer's name, address and telephone number.
„ Refer to the Warranty and Service section for the
Manufacturer's limited warranty.
Application Guidelines/Water Supply Parameters
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
18
Average
Minimum %
Average %
Effluent
Reduction
Reduction
0.0536 mg/L
97.03
97.39
2325 #/mL
99.51
99.9
Minimum %
Average %
Reduction
Reduction
99.67
99.29
99.50
99.14
96.54
96.25
91.57
82.72
92.22
96.88
98.58
99.97
93.33
92.77
City or Well
30 - 120 psi (207 - 827 kPa)
33° - 100°F (0.6° - 37.8°C)
0.5 GPM (3.2 Lpm) @ 60 psi.