Oil level inspection
- Wait a few minutes if the motorcycle has been operating.
(A)
- If the level is low, add the necessary quantity of oil by opening the
plug (C). Use the same type and oil manufacturer used currently
with the engine.
Transmission Oil
Viscosity: SAE 10W30.
Capacity: 1000 cc.
- Check the oil level
through the
inspection window
in the lower right
hand side of the
engine (A).
- Oil level must be
kept between the
maximum and
minimum marks.
(B)
-
If the lever is too
high, you have to
remove the excess
oil through the drain
plug
(B).
EC / MC / SM 2005 -
Oil change
NOTE
The engine must be completely cool and then warm up the
engine again for a few minutes to normal operating temperature,
to register the correct engine oil temperature and to obtain an
accurate oil level measurement.
- The transmission oil should be changed periodically to ensure
long engine life.
- Warm up the engine for 5 minutes so any oil sediment will float.
- Stop the engine, and place an oil pan under the engine.
- Remove the drain screw (see previous photo) and place the
motorcycle in riding position to allow the oil to drain out.
- Clean the drain screw magnet of any iron particles.
- Tighten the oil drain screw with its O-ring to 20-Nm.
- Remove the oil filler opening plug (C) and pour 900 cc of new
transmission oil for the models 200/ 250/ 300, and 650 cc for
model 125.
- Check the oil level, after kicking the kick-start pedal 3 or 4 times.
- Install the oil filler opening plug.
125 cc.
(C)
86
-
200/250/300 cc.
(C)

Hide quick links: