Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
ILLKO Manuals
Test Equipment
REVEXmax W
User manual
ILLKO REVEXmax W User Manual
Hide thumbs
1
2
Table Of Contents
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
page
of
68
Go
/
68
Contents
Table of Contents
Bookmarks
Table of Contents
Table of Contents
1 Introduction
Safety
Performance Revexmax
Applied Standards
Terms and Definitions
2 Description of the Instrument
General Description
Terminals
Keyboard
Additional Functions
Display of Information
Graphic OLED Display
Selection of the Items in Menu or List
Users Interface Symbols
Abbreviations
Included in the Set
Optional Accessories
3 Putting into Operation
Connecting to Mains Outlet
Self-Test
Help Screens
4 Measurements
Selection of the Function
Measurement Mode Control
Measurement Mode
HOLD Function
Measurement of Apparent Power Consumption
Earth Bond - Rpe
Test Lead Resistance Compensation
Protective Earth Resistance
Insulation Resistance - Riso
Alternative Method - Ialteq
Protective Class I Appliances
Protective Class II Appliances - Alternative Touch Leakage Current
PE Current During Operation - Idireq / Differential Leakage Current - Idifeq
Protective Class I One-Phase Appliances
Three-Phase and Hard-Wired Appliances
Touch Leakage Current - Idirtouch / Idiftouch / Idirw
Protective Class II Appliances
Protective Class I Appliances
Welding Equipment Output Leakage Current
Apparent Power, Mains Voltage and Current Consumption - Power
Power, Mains Voltage and Current Consumption in Test Socket
Measuring of Power and Current Consumption by Means of Current Clamp
Automatic Testing Extension Power Supply Cords
Welding Equipment Output Voltage - Uo
External Voltage Measurement - Voltmeter
5 Database Operations
Storing Measurement Data
The Structure of the Data Memory
Entering Characters
Identification Number of Device under Test (ID)
Working with Test Results
Viewing a List of Tested Duts
Searching for Stored Duts
Creating a New DUT File
Deleting a DUT from the Main Memory
Modification of the ID Number
Viewing Measured Values and Evaluation
Modification of Measured Values and Evaluation
Test Sequences
Description of the Test Sequence
Creating a Test Sequence
Assigning a Test Sequence to Appliance
Using the Test Sequence
6 Instrument Main Menu
Main Menu Structure
Menu - DUT Properties
Menu - Measured Values
Menu - Visual Inspection Result
Menu - Functional Test Result
Menu - Measurement Result
Menu - Test Sequences
Menu - Empty File
Menu - Setup
Menu - System Info
Menu - Self-Test
Menu - Date of Next Calibration
Menu - Erase Database
Menu - Measurement Locking
Menu - Save Last Method
Menu - Date and Time
Menu - Keys Beep
Menu - Volume
Menu - Language
7 Additional Information
Communication - Data Transfer
Messages on the Display
Warning Messages
Operational Information
Setting Information
Database Information
Reset of the Instrument
To Use Special Accessories
Carrying Bag for Instrument (P 6150)
Adapter for Testing Extension Power Supply Cords (P 8030)
Set of Adapters ATP for Automatic Testing Extension Power Supply Cords (P 8080)
Three-Phase Adapter (P 8015-8018)
Maintenance
Fuse
Recurrent Tests and Testing after Repair
Calibration and Service
Ecology
8 Technical Specification
General Data
Functions
Earth Bond
Insulation Resistance
Alternative Leakage Current
Direct Leakage Current
Differential Leakage Current
Leakage Current by Means of Three-Phase Adapter
Apparent Power
Mains Voltage U
Current Consumption
Current Consumption by Means of Current Clamp
Apparent Power by Means of Current Clamp
External Voltage DC (WELD Variant Only)
External Voltage AC (WELD Variant Only)
Welding Equipment Output Voltage (WELD Variant Only)
Advertisement
Quick Links
Download this manual
REVEXmax S
REVEXmax W
User's Manual
Version 1.1
05/2019
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Need help?
Do you have a question about the REVEXmax W and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for ILLKO REVEXmax W
Test Equipment ILLKO REVEXplus USB User Manual
(35 pages)
Test Equipment ILLKO REVEXmax S User Manual
(68 pages)
Test Equipment ILLKO ESC 2051 User Manual
(64 pages)
Test Equipment ILLKO GIGATEST pro User Manual
(25 pages)
Test Equipment ILLKO ZEROTESTpro User Manual
(26 pages)
Summarization of Contents
Introduction
Safety
Read manual, follow instructions for safe operation of the instrument and DUTs.
Performance REVEXmax
Overview of the REVEXmax S/W capabilities and scope of use.
Applied Standards
List of applied EMC and safety standards for the REVEXmax.
Terms and Definitions
Glossary of terms used in the manual, including symbols.
Description of the Instrument
General Description
Instrument purpose, main tests performed, and features.
Terminals
Detailed description and labeling of all instrument connection terminals.
Keyboard Functions
Explanation of the functions of each key on the REVEXmax keypad.
Additional Functions and Display
Details on HELP, ARET lock, scroll, save, menu, display elements, and symbols.
User Interface Symbols
Explanation of various symbols used in the user interface.
Abbreviations and Included Accessories
List of abbreviations and accessories provided with the REVEXmax.
Optional Accessories
List of optional accessories available to extend instrument functionality.
Putting into Operation
Connecting to Mains Outlet
Procedure for safely connecting the REVEXmax to a power outlet.
Self-Test Procedure
Procedure to perform a self-test to verify the instrument's basic functionality.
Help Screens Access
How to access and use the instrument's integrated help screens.
Measurements
Function Selection and Mode Control
Methods for selecting functions and controlling measurement modes.
HOLD Function and Power Measurement
Using HOLD function and how apparent power is displayed.
Earth Bond Resistance (Rpe)
Procedure for measuring protective earth bond resistance and test lead compensation.
Insulation Resistance (Riso)
Procedure for measuring insulation resistance at 500V and 250V.
Alternative Leakage Current (IaltEq)
Procedure for measuring alternative leakage current on Class I and II appliances.
PE and Differential Leakage Current
Measuring PE current during operation and differential leakage current.
Touch Leakage Current
Measuring touch leakage current for Class I and II appliances.
Welding Equipment Leakage Current
Measuring leakage current for welding equipment outputs (WELD variant).
Power, Voltage, and Current Measurements
Measuring apparent power, mains voltage, and current consumption.
Extension Cord and Voltage Measurements
Testing extension cords and using the instrument as a voltmeter.
Database Operations
Storing Measurement Data
How measurement data is stored, structured, and assigned a unique ID.
Entering Device IDs
Procedures for entering and managing Device Under Test (DUT) identification numbers.
Working with Test Results
Viewing, searching, and modifying test results and DUT files.
Test Sequence Management
Description, creation, assignment, and usage of automated test sequences.
Instrument Main Menu
Main Menu Structure
Overview of the main menu categories and their organization.
Menu - DUT Properties
Accessing and managing properties related to the device under test.
Menu - Test Sequences
Viewing and managing available test sequences for assignment.
Menu - Setup Options
Accessing and configuring instrument setup options like system info, self-test, and date.
Additional Information
Communication and Data Transfer
Instructions for transferring measurement data between the instrument and a PC.
Display Messages and Warnings
Explanation of various messages, warnings, and operational status indicators.
Instrument Reset and Maintenance
Procedure for resetting the instrument, plus maintenance and fuse replacement.
Special Accessories Usage
Instructions for using carrying bag, extension cord adapters, and three-phase adapters.
Calibration and Service Information
Information on recommended calibration intervals and contact details for service.
Technical Specifications
General Data
General technical specifications including protective class, voltage, and environmental conditions.
Earth Bond Specifications
Technical specifications for Earth bond measurements (range, resolution, error).
Insulation Resistance Specifications
Technical specifications for Insulation resistance measurements.
Leakage Current Specifications
Specs for Alternative, Direct, and Differential leakage current measurements.
Power, Voltage, and Current Specs
Specifications for Apparent power, Mains voltage, and Current consumption.
WELD Variant Specifications
Specifications for External voltage (AC/DC) and Welding equipment output voltage.
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the REVEXmax W and is the answer not in the manual?
Questions and answers