Page 4
Preface Thank you for using the MFSC 500W-1000W Series fiber laser products. We compile this document for you in order that the laser is used and maintained properly. Due to the limited level of the writers, coupled with time constraints, there are some careless mistakes in this document, and your understanding will be much appreciated.
Company Profile As a large laser manufacturer founded in 2004, Maxphotonics Co., Ltd. specializes in research and development, production and sales of lasers and ancillary products. Maxphotonics owns a number of independent intellectual property rights and patents as well as high-power pulsed fiber laser, high-power fiber laser and high-power fiber amplifier etc.
Chapter 1 Characteristic Explain MFSC CW Fiber Laser (MFSC500W-1000W) Series products provide a wide range of wavelength from 1060nm to 1100nm.The lasers are water-cooled and maintenance-free and with a wall plug efficiency of more than 25% and deliver high efficiency, high reliability, and high performance.
Chapter 2 General Safety Information 1 -Safety Conventions All safety warning symbols during operating process of the laser include: SYMBOLS DESCRIPTION WARNING : Refers to a potential Electrical Hazard to human body. It requires a procedure that, if not correctly followed, may result in bodily harm to you and/ or others.
Chapter 2 General Safety Information NOTE : ◎ This device is classified as a high power Class IV laser instrument. It may emit up to 1000W average power from 1060nm to 1100nm. This level of light may cause damage to the eye and skin. Despite the radiation being invisible, the beam may cause irreversible damage to the retina.
Chapter 2 General Safety Information 3-Reference Standard Electromagnetic Compatibility Emission EN 55011:5009+A1:2010 CISPR 11:5009+A1:2010 FCC Class A Anti-interference Performance on Electromagnetic Compatibility EN 61000-3-2:5006+A1:5009+A2:5009 EN 61000-3-3:5008 EN 61326-1:5006 EN 61000-4-2:5009 EN 61000-4-3:5006+A1:5007+A2:2010 EN 61000-4-4:5004+A1:2010 EN 61000-4-5:5006 EN 61000-4-6:5009 EN 61000-4-11:204 Others-Electromagnetic Compatibility Classification A of digital instrument complies with Canada ICES-8003 Power Supply Security...
Chapter 2 General Safety Information Please note : ◎ Performances of Maxphotonics MFSC laser meet the CE EMC certification requirements, the EMC requirements specified in "EMC Directive" of European market, the anti-interference requirements specified in "EMC" standard EN55011 emission and EN61326-1: 8006, and the emission requirements of group 1 classification A specified in EN55011.
Page 13
Chapter 2 General Safety Information elements that may be damaged from exposure to the laser light, video cameras, photomultipliers and photodiodes, need related protections. WARNING: ◎ The Maxphotonics MFSC laser light is strong enough to cut or weld metal, burn skin, clothing and paint. In addition, this light can ignite volatile substances such as alcohol, gasoline, ether and other solvents.
Page 14
Chapter 2 General Safety Information (10)Carry out commissioning, calibration and focusing at low output power and then increase the output power gradually when the calibrating and focusing work is done. (11)If the equipment is operated in a manner not specified in this document, the protection devices and performance of the equipment may be impaired and the warranty will be voided.
Page 15
Chapter 2 General Safety Information 4、Electrical Operating Instructions We strongly recommend that you read the following procedures before operating the laser : (1)Make sure the shell of this equipment is properly grounded. Any interruption of the ground loop may result in personal injury. (2)Make sure the power source connecting equipment is properly grounded.
Page 16
Chapter 2 General Safety Information 5、 Environment conditions and precautions For ensuring the safety of the laser working area, suitable enclosures shall be applied, including but not limited the laser safety signs and the interlocking devices. Corresponding operators must be trained and examined and know the normal safety specifications for operating the laser.
Chapter 2 General Safety Information 5-Additional Safety Information For additional information regarding Laser Safety, please refer to the list below: Laser Institute of America(LIA) 13501 Ingenuity Drive, Suite 128 Orlando,Florida 32826 Phone:407 380 1553,Fax: 407 380 5588 Toll Free:1 800 34 LASER American National Standards Institute ANSI Z136.1, American National Standard for the Safe Use of Lasers (Available through LIA)
Chapter 3 Product Description 1-Property Introductions As high power lasers developed for industrial application, MFSC Series lasers are compact and efficient. The lasers are mainly applied to the fields of welding, cutting, brazing, etc. Main Features: (1) High-quality laser output (2) High power, high efficiency (3) High reliability, long service life (4) Compact, rugged package...
Chapter 3 Product Description 3-Laser Model Designation Codes Model Coding Rules Model Model Coding Rules MFSC-500W Maxphotonics Single-mode CW Fiber Laser 500W MFSC-800W Maxphotonics Single-mode CW Fiber Laser 800W MFSC-1000W Maxphotonics Single-mode CW Fiber Laser 1000W 4-Certification Maxphotonics certifies that this equipment has been thoroughly tested and inspected and meets published specifications prior to shipping.
Chapter 3 Product Description 5-Front Panel Description Front Panel Description ITEMS FUNCTION DESCRIPTION (OFF ON) Key Switch Power switch of laser (Emergency stop) Emergency stop Emergency Stop Switch (Start) Start Switch Start laser (on-off signal of hardware) ALARM Abnormal situation light of laser ACTIVE Normal situation light of laser POWER...
Chapter 3 Product Description ITEMS FUNCTION DESCRIPTION CTRL External control connector RS232 RS232 connector AC220 220VAC power input POWER Leakage protection switch WATER OUT Water cooling output port WATER IN Water cooling input port 7-Optical Output Terminal 1 、Optical Output Head The optical output head come with a protective window that can be replaced if damaged.
Chapter 4 Specification 1 -Optical Characteristic Parameters Characteristics Test conditions Min. Nom. Max. Unit Operation mode CW/Modulated Polarization Random Output power 500W 100%CW Output power 800W 100%CW Output power 1000W 100%CW 1000 Tuning range of output power Emission wavelength 100%CW...
Chapter 5 Operating Guidance 1 - Disassembly Step The laser belongs to the precise valuables, so Maxphotonics recommends the following steps to unpack the packing box. Please unpack according to the following steps: ) (1 Place the packing box containing the laser on a horizontal platform such as the floor or a large table.
Chapter 5 Operating Guidance 2 -Packing List Names of fittings Description Unit Quantity Fiber Laser MFSC(500W-1000W) Piece 220VAC power wire Piece External signal wire 3.5 M Piece Shielded RS232 cable with RS232 signal wire Piece Female head on both ends Power Keys Piece USB disk...
Chapter 6 Operation Guide 1 - Notice Caution : ◎ Please refer to Section "Detail Specification Table" for proper electrical power. ◎ Refer to Section "General Safety Instructions" for inspecting whether the configuration environment of peripheral work of the laser meets the requirements.
Chapter 6 Operation Guide 3- Extension Interface For ensuring the communication between the laser and the board card, Maxphotonics adopts the high-quality HARTING terminal and provides the CTRL interface connectors. The interface definition is shown in the figure below. CTRL Interface Definition CTRL FUNCTION INTERFACE...
Chapter 6 Operation Guide Fault output 1 and 2 off Brown Fault output 1 when alarm on Brown and Fault output 2 Fault output 1 and 2 on white when alarm off Blue Blue and white NC External Control Signal Timing Emission Enable Input Laser Modulation...
Page 31
Chapter 6 Operation Guide CAUTION: ◎ It is imperative that the protective lens are checked for dirt, dust, or damage before you use the fiber connector. It will lead to heavy damage if the laser equipped with dirty or damaged fiber connector. ◎...
Page 32
Chapter 6 Operation Guide the surface, cleaning is necessary: 1. Put a few drops of alcohol onto the lint free swabs and throw away the excessive alcohol. 2. Place the swabs on the dust via microscope. 3. Cleaning the dust carefully, and move it to the edge of lens.
Page 33
Chapter 6 Operation Guide Cleaning protective lens with swabs IMPORTANT: ◎ Do not reuse a lint-free optical wipe or swab. ◎ Do not touch the protective lens of the fiber connector. ◎ Do not blow directly, or else new dirty will be brought. ◎...
Chapter 6 Operation Guide 5-Start Step WARNING: ◎ Make sure that all the electrical connections (including cooling water connections) are connected prior to use. All the connectors must be held steady with screws if possible. ◎ NEVER look directly into the output fiber and make sure that you wear the laser safety eyewear while operating the product.
Chapter 6 Operation Guide 7- Software Description (1)Installment software is saved in USB DISK. (2)Click right button to unzip the files to D. (3)Double click setup document, finish installment guide. (4)Double click desktop shortcut to open the program, access to the following connect interface: Use the serial interface cable which is enclosed with the device, connect the laser and PC, select a port number, click “connect”...
Chapter 6 Operation Guide 8-Error Listing The fault alarm points set by the laser include: Message Descripion Trouble shooting Operation leads to low output Laser internal Front lamp power of laser such as low light path warning modulation frequency, low peak testing fault power, low cutting power For the internal overheat fault of...
Page 38
Chapter 6 Operation Guide If the laser has internal overvoltage, please check whether the AC Overvoltage Overvoltage voltage is within the range warning fault of laser of 200~240V.If this cause is excluded,please contact Maxphotonics. The fault will be produced when QBH head is not inserted in the Install error of QBH warning...
Chapter 7 Service and Maintenance 1- Maintenance Notes CAUTION ; ◎ No operator serviceable parts inside. Refer all servicing to qualified Maxphotonics personnel. ◎ For ensuring that the repairs or replacement within the warranty scope can be carried out, and perfectly maintaining your interests, please submit application to the Maxphotonics or the local representative after finding the faults.
Chapter 7 Service and Maintenance 2-Service Statements More problems regarding the safety, set-up, operation or maintenance can be solved by carefully reading this "User Guide". Please call the Customer Service Department for other questions. If your problems cannot be solved over the telephone with our t e c h n i c a l s u p p o r t g r o u p , y o u m a y n e e d t o r e t u r n t h e p r o d u c t t o Maxphotonics for further troubleshooting.
Chapter 8 Warranty Statements 1-General Items Maxphotonics carries out warranty for any defect of the product caused by its material and production technology within the warranty period agreed in contract, and ensures that its product meet the relevant quality and specification requirements specified in the document under normal use condition.
Page 42
Chapter 8 Warranty Statements (5) Improper installation or maintenance, or operating under conditions not included in this manual; (6) The fittings and the fiber connectors are not included in the warranty scope. Customers are obligated to understand the information above and operate according to the User Guide and specification, or the faults arising therefrom are not included in the warranty scope.
Need help?
Do you have a question about the MFSC 1000W Series and is the answer not in the manual?
Questions and answers