SPECIFICATIONS

CCL3018PR
CCL3018PRA CCL3018NRA
Btu (Variable)
16,000/30,000
Type Gas
Propane/LP Only Natural Gas Only
Ignition
Piezo
Manifold Pressure
8.0" W.C.
Inlet Gas Pressure (in. of water)
Maximum
14"
Minimum*
11"
Shipping Weight
28 lbs.
* For the purpose of input adjustment
CCL3924PR
CCL3924PRA CCL3924NRA
Btu (Variable)
20,000/39,000
Type Gas
Propane/LP Only Natural Gas Only
Ignition
Piezo
Manifold Pressure
8.0" W.C.
Inlet Gas Pressure (in. of water)
Maximum
14"
Minimum*
11"
Shipping Weight
66 lbs.
* For the purpose of input adjustment
CCL3930PR
CCL3930PRA CCL3930NRA
Btu (Variable)
20,000/39,000
Type Gas
Propane/LP Only Natural Gas Only
Ignition
Piezo
Manifold Pressure
8.0" W.C.
Inlet Gas Pressure (in. of water)
Maximum
14"
Minimum*
11"
Shipping Weight
70 lbs.
* For the purpose of input adjustment
For more information, visit www.desatech.com
For more information, visit www.desatech.com
111161-01A

SERVICE HINTS

CCL3018NR
When Gas Pressure Is Too Low
• pilot will not stay lit
16,000/30,000
• burners will have delayed ignition
• heater will not produce specified heat
• propane/LP gas supply may be low
Piezo
3.5" W.C.
You may feel your gas pressure is too low. If so, contact your local
propane/LP gas supplier.
10.5"
5"

TECHNICAL SERVICE

28 lbs.
You may have further questions about installation, operation, or
troubleshooting. If so, contact DESA International's Technical
CCL3924NR
Service Department at 1-866-672-6040. When calling, please have
your model and serial numbers of your heater ready.
You can also visit DESA International's technical service web site
20,000/39,000
at www.desatech.com.
For information or questions concerning hand-held remote or re-
Piezo
ceiver, contact Tracking Technology at 1-800-301-0440 or
3.5" W.C.
www.trackingtech.com.
10.5"

REPLACEMENT PARTS

5"
Note: Use only original replacement parts. This will protect your
66 lbs.
warranty coverage for parts replaced under warranty.
PARTS UNDER WARRANTY
CCL3930NR
Contact authorized dealers of this product. If they can't supply
original replacement part(s), call DESA International's Technical
20,000/39,000
Service Department at 1-866-672-6040.
When calling DESA International, have ready
Piezo
• your name
3.5" W.C.
• your address
• model and serial numbers of your heater
10.5"
• how heater was malfunctioning
5"
• type of gas used (propane/LP or natural gas)
70 lbs.
• purchase date
Usually, we will ask you to return the part to the factory.
PARTS NOT UNDER WARRANTY
Contact authorized dealers of this product. If they can't supply
original replacement part(s), either contact your nearest Parts Cen-
tral (see page 28) or call DESA International at 1-866-672-6040 for
referral information.
When calling DESA International, have ready
• model number of your heater
• the replacement part number
SPECIFICATIONS
SERVICE HINTS
TECHNICAL SERVICE
REPLACEMENT PARTS
23
23