WATER AND AIR UV STERILIZERS ® Manufactured in Poland WATER STERILIZERS V SERIES MODELS: V9;V12; V20; V20LA; V25; V25LA; V35; V40; V80; V120 MANUAL Patent no. 204935 Version - November 2018...
8.1. IN V9, V12, V20, V25, V35 ....................12 8.2. IN V20LA, V25LA, V40, V80, V120 ..................13 V SERIES STERILIZERS SERVICE ....................14 9.1. REPLACEMENT OF UV LAMP ..................... 14 9.2. RESETTING THE COUNTER IN THE ALARM SYSTEM / V20LA, V25LA, V40, V80, V120/ 14 9.3.
Page 3
UV RADIATION TMA UV Sterilizers use lamps that emit UVC radiation. The design of the sterilizers ensures the safety of the user. Direct exposure to UV radiation is harmful to human skin and sight. As a result of direct UV radiation, reddening of skin, serious burns or ultimately loss of eyesight may occur (depending on the time of exposure).
The detailed instructions of the new panel are provided on the casing of the electrical enclosure. Sterilizers of the V series have a steel muff with a hood that functions as a sight glass. This innovative solution of a light muff allows for optical control of the working condition of the lamp.
V9 – V120 2. Applications Disinfection with UV radiation is a reliable, simple and inexpensive method of sterilization. The use of this method is possible whenever microbiological risk exists. The applications of this method are, among many others: Potable water in private and municipal installations ...
UV LAMPS SHOULD BE REPLACED AFTER THEIR END OF LIFE TIME (SEE MANUAL) PARTS INSIDE FOR INDOOR USE ONLY www.tma.pl biuro@tma.pl +48 85 743 12 46 TMA / BIAŁOSTOCZEK 26, GM. ZABŁUDÓW / 15-592 BIAŁYSTOK / POLSKA TECHNICAL SPECIFICATIONS: Model V20LA ~220V-240V 50- ~220V-240V 50-...
Page 7
Additional charge Additional charge Additional charge Additional charge Additional charge Weight with Enclosure 5.9kg 8.6kg 9.8kg 10.2kg 11.5kg TMA Company reserves the right to make design changes without notice. Białostoczek 26,gm.Zabłudów,15-592 Białystok; Poland ; VAT PL5420008413; GIOŚ: E0021166WZ; Tel. +48 857431246...
V9 – V120 ATTENTION! Minimal flow of water is not required for the devices to work. Increased flow through the sterilizer lowers the efficiency of disinfection. The device is comprised of stainless steel chamber and electrical enclosure. 5.
V9 – V120 OUTLET DISINFECTED WATER WATER SAMPLE INLET TAKE-UP VALVE CONTAMINATED ELECTRICAL ENCLOSURE SHUT-OFF VALVES WATER FILTER min. 0,1 mm POWER LINE DISTANCE EQUAL TO THE LENGHT OF THE STERILISER HORIZONTAL MOUNTING ARRANGEMENT OF THE UV STERILISER 1) Temperature range for installation is from 5 to 45 2) Upstream of the intake install potable water filter.
V9 – V120 6. Connection of solenoid valve or leading the alarm signal out in V20LA, V25LA, V40, V80, V120 ELECTRICAL ENCLOSURE 1.REMOVE DOORS OF THE ELECTRICAL ENCLOSURE POWER POWER OUTLET DISINFECTED WATER SOLENOID VALVE WATER SAMPLE 2. TO THE TERMINALS 1 & 2 ON TAKEUP VALVE ELECTRONIC PLATE CONNECT SOLENOID VALVE OR ALARM SIGNAL...
V9 – V120 6.1. CONNECTION OF SOLENOID VALVE Connect solenoid valve type NZ (normally closed) max. 2A to the terminals 1 & 2 /neutral/ on the electronic plate in electrical enclosure. Contacts 1 & 2 start working after a preset time delay of 2-3 min – it is a time necessary for the device to become fully operational.
V9 – V120 In case of high turbidity and waste water, the choice of equipment and efficiency should be made by the dealer or producer. g) Sterilizers must be sized for the maximum momentary flow of water (matching them to the daily flows may result in incomplete disinfection).
V9 – V120 8.2. IN V20LA, V25LA, V40, V80, V120 Display indications Cause Solution L D 3 s . P R Z Y T R Z Y M A Ć 3 s . - 7 days left to the end of UV lamp life.
V9 – V120 9. V series sterilizers service 9.1. REPLACEMENT OF UV LAMP (graphic instructions at the end of the Manual) a) Disconnect the power supply, b) Allow for the lamp to cool down from operating temperature, Replacement of the UV lamp does not require the stop of fluid flow through the chamber...
V9 – V120 9.3. REPLACEMENT AND CLEANING OF THE QUARTZ SLEEVE /FRAGILE AND BRITTLE/ (graphic instructions at the and of the manual) a) Disconnect the power supply, b) Cut off the liquid flow through the chamber, c) Remove the water from the chamber, d) Allow for the lamp to cool down from operating temperature, e) Remove the UV lamp from the sleeve / see pt.
V9 – V120 Spare parts list V SERIES UV WATER STERILIZER V9– V120 – SPARE PARTS LIST TITLE 1 2 0 V20/ V25/ V120 No. PART 20LA V25LA pcs. 1 pc. 02.01 02.01 02.01 02.01 02.01 02.01 02.01 02.01 STRAIN RELIEF 1 pc.
V9 – V120 Graphic assembly instructions 11.1. ASSEMBLY OF THE STERILIZERS WITH BRACKETS – V20,V20LA,V35,V40, V80, V120 WHEN THE STERILIZER IS MOUNTED HORIZONTALY THE INLET END OUTLET CAN BE LOCATED AT EITHER END. 1.LOOSEN THE SCREW AND ADJUST THE POSITION OF THE CHAMBER FOR THE INSTALLATION NEEDS 2.TIGHTEN THE SCREWS.
V9 – V120 11.2. ASSEMBLY OF THE ELECTRICAL ENCLOSURES IN V20LA, V25LA, V40, V80, V120 Option I Option II Option I Option II Białostoczek 26,gm.Zabłudów,15-592 Białystok; Poland ; VAT PL5420008413; GIOŚ: E0021166WZ; Tel. +48 857431246...
Warranty 1. UV sterilizers are used to sterilize water/liquids from a known source. 2. The manufacturer, TMA company, warrants faultless operation of the devices covered by this Warranty. 3. The conditions for warranty claims during the warranty period are: ...
21. Warranty claims may relate only to the replacement or repair of defective parts of UV sterilizers. THE WARRANTY SHALL NOT COVER DEVICES NOT BEARING THE TMA LOGO. Białostoczek 26,gm.Zabłudów,15-592 Białystok; Poland ; VAT PL5420008413; GIOŚ: E0021166WZ;...